StarTech.com RKPW081915

StarTech.com 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (RKPW081915) Instruction Manual

Model: RKPW081915

1. تعارف

This manual provides instructions for the installation, operation, and maintenance of your StarTech.com 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (Model RKPW081915). This Power Distribution Unit (PDU) is designed to provide reliable power distribution and surge protection for equipment within network server racks and cabinets.

2. حفاظتی معلومات

WARNING: Failure to follow these safety instructions may result in fire, electric shock, or other injury or damage.

  • مصنوعات کو چلانے سے پہلے تمام ہدایات پڑھیں۔
  • یہ پروڈکٹ صرف انڈور استعمال کے لیے ہے۔
  • Ensure the PDU is properly grounded. Do not use with ungrounded outlets.
  • Do not exceed the maximum electrical rating of 120V/15A. Overloading the PDU can cause damage and fire hazards.
  • Do not disassemble or modify the PDU. Refer all servicing to qualified personnel.
  • Keep away from water or excessive humidity.
  • Do not plug one PDU into another.

3. پیکیج کے مشمولات

StarTech.com RKPW081915 PDU and Instruction Manual in packaging

Image: The StarTech.com PDU and its instruction manual, as typically found in the product packaging.

  • 1x 8 Outlet Horizontal 1U Rack Mount PDU Power Strip (RKPW081915)
  • 1x ہدایت نامہ

4. پروڈکٹ ختمview

The StarTech.com RKPW081915 is a 1U horizontal rack-mountable PDU designed for efficient power distribution in server environments. It features 8 NEMA 5-15R outlets, a 6-foot power cord, and built-in surge protection.

فرنٹ پینل کی خصوصیات

آگے اور پیچھے view of the StarTech.com RKPW081915 PDU with labeled components

تصویر: تفصیلی view of the PDU's front and back, highlighting the LED indicators, power switch, and outlets.

  • LED Surge Indicator: جب اضافی تحفظ فعال ہوتا ہے تو روشن ہوتا ہے۔
  • LED Ground Indicator: Illuminates when the PDU is properly grounded.
  • Power/Reset Switch: Controls power to all outlets and acts as a circuit breaker reset.

ریئر پینل کی خصوصیات

  • 8 x NEMA 5-15R Outlets: Provides power connections for your equipment.
  • Integrated 6ft Power Cord: Connects the PDU to a power source.
پیچھے view of the StarTech.com RKPW081915 PDU showing the 8 NEMA 5-15R outlets and power cord

Image: Close-up of the rear of the PDU, displaying the eight power outlets and the attached power cord.

5. سیٹ اپ

5.1 پیک کھولنا

Carefully remove the PDU and all components from the packaging. Inspect for any damage during shipping. If any damage is found, contact your vendor immediately.

5.2 ریک ماؤنٹنگ

The RKPW081915 PDU is designed for horizontal mounting in any standard 19-inch server rack that is 4 inches (10.16 cm) deep or greater. It occupies 1U of rack space.

  1. Align the mounting ears of the PDU with the desired rack unit (U) on your server rack.
  2. Secure the PDU to the rack using appropriate rack screws (not included). Ensure both sides are firmly attached.
StarTech.com RKPW081915 PDU installed horizontally in a server rack

Image: The PDU mounted horizontally within a server rack, demonstrating its 1U form factor and integration with other equipment.

StarTech.com RKPW081915 PDU with dimensions and rack compatibility information

Image: A visual representation of the PDU's height (1U) and cable length (6ft), confirming its compatibility with standard 19-inch racks.

5.3 کنیکٹنگ ڈیوائسز

  1. Ensure the PDU's power/reset switch is in the OFF position.
  2. Plug the power cords of your network and server equipment into the 8 NEMA 5-15R outlets on the rear of the PDU.
  3. Connect the integrated 6-foot power cord of the PDU to a grounded 120V/15A power source.

Video: Demonstrates the installation of a rack-mounted power strip, showing how it integrates into a server rack and connects to devices.

Video: An official product video from StarTech.com showcasing the 8 Outlet Horizontal 1U Rack Mount PDU Power Strip for network server racks, highlighting its surge protection features.

Video: A demonstration of the StarTech 8 Outlet Horizontal 1U Rack Mount PDU, showing its physical attributes and how it fits into a rack setup.

ویڈیو: ایک اوورview of an 8 Outlet Rack-Mount PDU, detailing its features and benefits for organizing power in a rack system.

Video: A demonstration of a PDU Outlet Horizontal, highlighting its design and functionality for power distribution.

6. آپریٹنگ ہدایات

6.1 پاور آن/آف۔

To power on the connected equipment, press the Power/Reset switch on the front panel to the ON position. To power off, press the switch to the OFF position.

6.2 ایل ای ڈی اشارے

  • Surge LED (Green): When illuminated, it indicates that the surge protection feature is active and functioning. If this LED is off, the surge protection has been compromised, and the unit should be replaced.
  • Ground LED (Green): When illuminated, it indicates that the PDU is properly grounded. If this LED is off, there may be a grounding issue with your power source or the PDU itself.

6.3 سرکٹ توڑنے والا

The Power/Reset switch also functions as a circuit breaker. If an overload occurs, the switch will trip to the OFF position, cutting power to all connected devices to prevent damage. To reset the circuit breaker, reduce the load on the PDU and then press the switch back to the ON position.

7 دیکھ بھال

7.1 صفائی

To clean the PDU, ensure it is powered off and disconnected from the main power source. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.

7.2 باقاعدہ چیکس

  • Periodically check the Surge and Ground LEDs to ensure they are illuminated, indicating proper function and grounding.
  • Inspect the power cord and connected device cords for any signs of damage or wear.
  • یقینی بنائیں کہ تمام کنکشن محفوظ ہیں۔

8 خرابیوں کا سراغ لگانا

مسئلہممکنہ وجہحل
منسلک آلات کی طاقت نہیں ہے۔PDU is off or circuit breaker tripped.Ensure the Power/Reset switch is ON. If it tripped, reduce the load and reset the switch.
Ground LED is off.نامناسب گراؤنڈنگ۔Ensure the PDU is plugged into a properly grounded outlet. Check the building's electrical wiring.
Surge LED is off.Surge protection has been compromised.The PDU's surge protection may no longer be active. Replace the unit to ensure continued protection.
Devices are not receiving enough power.PDU is overloaded.Reduce the total power draw of connected devices to stay within the 15A limit.

9. وضاحتیں

فیچرتفصیل
ماڈل نمبرRKPW081915
برانڈاسٹار ٹیک ڈاٹ کام
کل پاور آؤٹ لیٹس8 x NEMA 5-15R
ان پٹ جلدtage120 وولٹ اے سی
موجودہ درجہ بندی15 Amps
پاور کورڈ کی لمبائی6 فٹ (1.8 میٹر)
Rack Unit (RU)1U
چڑھناHorizontal 19-inch Rack Mount
طول و عرض (LxWxH)19 x 3.76 x 1.68 انچ (48.26 x 9.55 x 4.27 سینٹی میٹر)
شے کا وزن4.85 پاؤنڈ (2.2 کلوگرام)
خصوصی خصوصیاتMountable, On/Off Switch, Surge Protection, Built-in Circuit Breaker
Casinجی موادRugged Steel

10. وارنٹی اور سپورٹ

This StarTech.com product is backed by a lifetime warranty, ensuring long-term reliability and peace of mind. In addition, free lifetime 24/5 multi-lingual technical assistance is available to help you with any questions or issues you may encounter.

For technical support or warranty claims, please visit the official StarTech.com webسائٹ یا ان کی کسٹمر سروس سے براہ راست رابطہ کریں۔ وارنٹی کی توثیق کے لیے اپنی خریداری کی رسید اپنے پاس رکھیں۔

© 2024 StarTech.com. All rights reserved.