1. تعارف
The Inkbird ITC308S is a reliable and easy-to-use temperature controller designed for precise temperature management in various applications, particularly aquariums. It features dual relay outputs for both heating and cooling devices, ensuring stable temperature control. The unit includes a fully submersible probe for accurate temperature readings in liquid environments.
2. حفاظتی معلومات
- Ensure the power supply matches the controller's requirements (110V for this model).
- Do not immerse the main controller unit in water. Only the probe is submersible.
- کسی بھی دیکھ بھال یا تنصیب کو انجام دینے سے پہلے ہمیشہ بجلی منقطع کریں۔
- آلے کو بچوں اور پالتو جانوروں سے دور رکھیں۔
- اگر کوئی حصہ خراب ہو جائے تو آلہ استعمال نہ کریں۔
3. پیکیج کے مشمولات
- ITC308S Temperature Controller Unit
- Submersible Temperature Probe
- Suction Cup for Probe Mounting
- صارف دستی

تصویر 3.1: The Inkbird ITC308S Temperature Controller and its included accessories, packaged in a brown box.
4. پروڈکٹ ختمview
The ITC308S features a main control unit with a dual LED display, showing both the present value (PV) and set value (SV) temperatures. It has dedicated outlets for heating and cooling devices, and a detachable submersible probe for accurate temperature sensing.

تصویر 4.1: ختمview of the Inkbird ITC308S controller, showing the display, control buttons, power cord, and probe connection.

تصویر 4.2: The dual power outlets, clearly marked for 'HEATING' and 'COOLING' devices.

تصویر 4.3: The submersible temperature probe, designed for accurate readings in water, shown with its suction cup.
5. وضاحتیں
| فیچر | تفصیل |
|---|---|
| ماڈل | ITC-308S |
| والیومtage | 120 وولٹ (AC) |
| زیادہ سے زیادہ آؤٹ پٹ لوڈ | 1200W (110V) |
| درجہ حرارت کنٹرول موڈ | On/Off Control (Heating and Cooling) |
| تحقیقات کی قسم | Fully Submersible Aquarium Probe |
| ڈسپلے کی قسم | LED Dual Display |
| مواد | پلاسٹک |
| رنگ | Green, Gray and White |
6. سیٹ اپ ہدایات
- تحقیقات کو مربوط کریں: Plug the submersible temperature probe into the designated port on the main controller unit. Use the provided suction cup to secure the probe inside your aquarium or water bath, ensuring it is fully submerged and away from direct heat sources or strong currents.
- Connect Heating/Cooling Devices: Plug your heating device (e.g., aquarium heater) into the 'HEATING' outlet and your cooling device (e.g., cooling fan) into the 'COOLING' outlet on the power strip. Ensure devices are rated within the controller's maximum output load (1200W).
- پاور آن: Plug the main power cord of the ITC308S controller into a standard 110V AC power outlet. The LED display will illuminate, showing the current temperature (PV) and the set temperature (SV).

تصویر 6.1: The submersible probe correctly placed within an aquarium, ensuring accurate temperature measurement.
7. آپریٹنگ ہدایات
- View Current Temperature (PV): The upper LED display shows the current measured temperature (Process Value).
- View Set Temperature (SV): The lower LED display shows the desired set temperature (Set Value).
- درجہ حرارت مقرر کریں:
- دبائیں سیٹ button once. The SV display will flash.
- استعمال کریں۔ اوپر (▲) or نیچے (▼) مطلوبہ درجہ حرارت کو ایڈجسٹ کرنے کے لئے بٹن۔
- دبائیں سیٹ again to confirm and save the setting, or wait a few seconds for it to save automatically.
- Heating/Cooling Indication: The 'HEATING' or 'COOLING' indicator lights will illuminate when the respective outlet is active.
- درجہ حرارت کیلیبریشن: Refer to the detailed instructions in the included paper manual for advanced settings like temperature calibration, differential settings, and alarm parameters. These settings allow fine-tuning of the controller's response.
- الارم: The controller features over-temperature and sensor fault alarms. If an alarm triggers, the display will show an error code (e.g., 'HHH' for over-temperature, 'LLL' for under-temperature, 'ERR' for sensor fault) and an audible alert may sound. Address the issue promptly.
8 دیکھ بھال
- تحقیقات کی صفائی: Regularly inspect and clean the submersible probe to prevent algae or mineral buildup, which can affect accuracy. Use a soft cloth and mild cleaning solution if necessary.
- کنٹرولر یونٹ: Wipe the main controller unit with a dry, soft cloth. Do not use abrasive cleaners or immerse it in water.
- کیبل معائنہ: Periodically check all cables for any signs of wear, cuts, or damage. Replace if necessary.
9 خرابیوں کا سراغ لگانا
| مسئلہ | ممکنہ وجہ | حل |
|---|---|---|
| ڈسپلے خالی ہے | بجلی کی فراہمی نہیں ہے۔ | بجلی کا کنکشن اور آؤٹ لیٹ چیک کریں۔ |
| درجہ حرارت پڑھنا غلط ہے۔ | Probe dirty or improperly placed; calibration needed | Clean probe, ensure proper submersion, perform temperature calibration. |
| ہیٹنگ/کولنگ ڈیوائس آن نہیں ہو رہی ہے۔ | Device not plugged in correctly; controller settings incorrect; device malfunction | Verify device connection to correct outlet, check set temperature and differential, test device independently. |
| Alarm sounds frequently | Temperature outside set range; alarm limits too narrow | Adjust set temperature or alarm high/low limits. Ensure heating/cooling devices are functioning. |
| 'ERR' displayed | سینسر کی خرابی۔ | Check probe connection. If error persists, the probe may need replacement. |
10. وارنٹی اور سپورٹ
Inkbird products are designed for reliability and performance. For warranty information, technical support, or service inquiries, please refer to the contact details provided in your product packaging or visit the official Inkbird webسائٹ وارنٹی کے دعووں کے لیے اپنی خریداری کی رسید اپنے پاس رکھیں۔