DROK 200536FBA

DROK Bidirectional Volt Amp Meter (Model 200536FBA) Instruction Manual

تعارف

This manual provides detailed instructions for the installation, operation, and maintenance of the DROK Bidirectional Volt Amp Meter, Model 200536FBA. This 7-in-1 monitor is designed to measure DC voltage, current, power, battery capacity, amp-hour, watt-hour, and time, featuring a clear color LCD display and a Hall sensor for non-contact current measurement.

مصنوعات کی خصوصیات

  • 7 میں 1 پیمائش: Simultaneously displays DC voltage (0-90V), current (0-300A), power, battery capacity, amp-hour, watt-hour, and time on a 1.8-inch LCD color screen.
  • Bidirectional Ammeter: Detects current flow in both charging and discharging directions without requiring changes to wiring.
  • Comprehensive Protection Functions: Includes Over-Voltage Protection (OVP), Over-Current Protection (OCP), Over-Power Protection (OPP), Low-Voltage Protection (LOP), Over-Charge Protection (OAH), and Over-Time Protection (OFT).
  • میموری فنکشن: AH power-off memorized function retains data.
  • Reset and Calibration: Features time and AH reset functions, along with a calibration capability for accurate readings.
  • ڈسپلے کنٹرول: LCD screen can be switched off automatically or manually.
  • آؤٹ پٹ کنٹرول: Connects to a relay (not included) for enabling/disabling output via a control button.

پیکیج کے مشمولات

تصدیق کریں کہ تمام اشیاء پیکیج میں موجود ہیں:

  • 1x Charge-Discharge Monitor (Display Unit)
  • 1x Hall Sensor (Current Sensor)
  • 1x 50cm Shielding Wire (for connecting display to sensor)
DROK Bidirectional Volt Amp Meter components including display, Hall sensor, and connecting wires.

Image: The complete package contents, showing the display unit, Hall sensor, and the included shielding wire.

وضاحتیں

پیرامیٹرقدر
پیمائش کے پیرامیٹرزوالیومtage, Current, Power, Battery Capacity, Amp-Hour, Watt-Hour, Time
والیومtage پیمائش کی حدDC 0-90V
موجودہ پیمائش کی حدDC 0-300A
والیومtage پیمائش کی درستگی± 2% ± 5 ہندسے
موجودہ پیمائش کی درستگی± 3% ± 5 ہندسے
ڈسپلے ریزولوشن0.1A, 0.01V, 0.01AH, 0.01H (1 min)
پیمائش کی شرح5 بار / سیکنڈ
ڈسپلے1.8 inch LCD Color Screen
Meter Overall Dimension79 x 43 x 26 ملی میٹر (3.11 x 1.69 x 1.02 انچ)
Meter Opening Hole Size76.5 x 39.2 ملی میٹر (3.01 x 1.54 انچ)
ہال سینسر سائز57 x 32 x 50mm (2.24 x 1.26 x 1.97 inch) (with screw and copper pillars)
Hall Sensor Hole Diameter20 ملی میٹر (0.79 انچ)
اوور والیمtagای پروٹیکشن (OVP)0.01V-90V
موجودہ حالیہ حفاظت (OCP)0.1-100A
اوور پاور پروٹیکشن (OPP)0.01W-9.99KW
کم جلدtage Protection (LOP)0.01V-90V
Over-Charge Protection (OAH)0.01ھ-9999ھ
Over-Time Protection (OFT)1 منٹ - 99 گھنٹہ 59 منٹ
Dimensions of the DROK display unit and Hall sensor.

Image: Physical dimensions of the display unit and the Hall sensor for installation planning.

سیٹ اپ اور انسٹالیشن

Proper wiring is crucial for accurate measurements and safe operation. The Hall sensor measures current by passing the load wire through its central hole. The display unit requires a power supply (DC 10-60V) and connects to the Hall sensor via the provided shielding wire.

Wiring diagrams for the DROK Bidirectional Volt Amp Meter in three configurations.

Image: Three common wiring configurations for the meter, showing connections to battery, load, and optional relay.

Wiring Configuration 1: Basic Monitoring (Self-Powered)

In this configuration, the meter is powered directly from the battery being monitored. This is suitable for systems where the battery voltage is within the meter's operating range (10-60V).

  1. Connect the positive terminal of the battery to the 'Bat+' terminal on the Hall sensor.
  2. Connect the negative terminal of the battery to the 'Bat-' terminal on the Hall sensor.
  3. پاس کریں۔ منفی load wire through the central hole of the Hall sensor. Ensure the direction of current flow through the sensor matches the arrow on the sensor for correct bidirectional readings.
  4. Connect the display unit to the Hall sensor using the provided 50cm shielding wire.
  5. Ensure the jumper cap on the Hall sensor is placed to select the self-powered mode (typically labeled '10-60V' or similar, check the sensor board for exact markings).

Wiring Configuration 2: External Power Supply

Use this configuration when the battery voltage is outside the meter's operating range (e.g., 0-10V or above 60V) or if you prefer a separate power source for the meter.

  1. Connect the positive terminal of the battery to the 'Bat+' terminal on the Hall sensor.
  2. Connect the negative terminal of the battery to the 'Bat-' terminal on the Hall sensor.
  3. پاس کریں۔ منفی load wire through the central hole of the Hall sensor.
  4. Connect the display unit to the Hall sensor using the provided 50cm shielding wire.
  5. Connect an external DC power supply (10-60V) to the 'Vext+' and 'Vext-' terminals on the Hall sensor.
  6. Remove the jumper cap from the Hall sensor to enable external power mode.

Wiring Configuration 3: With Relay for Output Control

This setup allows the meter to control an external relay (not included) based on configured protection parameters (e.g., over-current, low-voltagای).

  1. Follow either Configuration 1 or 2 for basic power and measurement connections.
  2. Connect the relay's control terminals to the 'Relay+' and 'Relay-' terminals on the Hall sensor.
  3. Ensure the jumper cap is set correctly for the chosen power mode (self-powered or external).
  4. The meter's output control button can then be used to enable/disable the relay, or the relay can be triggered automatically by protection settings.

آپریٹنگ ہدایات

The DROK Volt Amp Meter features a user-friendly interface with a color LCD and three control buttons: Up, OK, and Down.

سامنے والا view of the DROK Bidirectional Volt Amp Meter display showing various readings and protection indicators.

Image: The main display interface, showing voltage, current, capacity, power, time, and protection status indicators.

ڈسپلے ختمview

The 1.8-inch color LCD simultaneously displays:

  • والیومtage (V): Top left, large font.
  • موجودہ (A): Below voltage, large font.
  • Battery Capacity (%): Graphical bar and percentage.
  • Amp-Hour (AH): Accumulated charge/discharge.
  • Watt-Hour (WH): Accumulated energy.
  • پاور (W): Instantaneous power.
  • Time (H): گزرا وقت.
  • Protection Indicators: OVP, OPP, OCP, OFT, OAH, LOP (Over-Voltage, Over-Power, Over-Current, Over-Time, Over-Charge, Low-Voltagای تحفظ)۔

بٹن کے افعال

  • اوپر تیر کا بٹن: Navigates upwards through menu options or increases values during settings.
  • نیچے تیر کا بٹن: Navigates downwards through menu options or decreases values during settings.
  • ٹھیک ہے بٹن: Enters menu, confirms selections, or toggles display modes (e.g., battery graph). Press and hold to access certain functions or calibration mode.

Resetting AH and Time

To reset accumulated Amp-Hours (AH) and Time, navigate to the relevant display screen using the arrow buttons. Press and hold the OK button until the values reset. This is useful for monitoring specific charge/discharge cycles.

انشانکن کا طریقہ کار

For optimal accuracy, calibration may be required. Follow these steps carefully:

  1. کیلیبریشن موڈ درج کریں: ڈیوائس کے پاور آف ہونے کے دوران، دبائیں اور دبائے رکھیں OK button. While holding OK, switch the power to the device ON. Release the OK button as soon as the display illuminates.
  2. Navigation in Calibration Mode: In calibration mode, press the OK button to move from one menu item to the next. Use the Up اور نیچے arrow keys to adjust values.
  3. Zero Current Calibration: Before calibrating current readings, ensure no current is flowing through the Hall sensor. Switch off all loads. Press OK until the "0.0 A" option is selected, then press the نیچے arrow once to zero out the current reading.
  4. Positive Current Calibration (+A): To calibrate current in the charging direction, ensure current is flowing from the charging source into your battery. Press OK until the "+A" option is selected, then use the arrow keys to adjust the reading to match a known accurate current measurement.
  5. Negative Current Calibration (-A): To calibrate current in the discharging direction, ensure current is flowing out of your battery into your loads. Press OK until the "-A" option is selected, then use the arrow keys to adjust the reading to match a known accurate current measurement.
  6. ترتیبات کو محفوظ کریں: After completing all calibrations, navigate the cursor to the "Save" option using the OK button. Select "Save" to store your settings.
  7. Exit Calibration Mode: To exit calibration mode, simply switch the power to the unit OFF, then ON again.

حفاظتی افعال

The meter includes several programmable protection functions to safeguard your system:

  • OVP (اوور والیومtagای تحفظ): Configurable from 0.01V to 90V. Triggers when voltage exceeds the set limit.
  • OCP (Over-Current Protection): Configurable from 0.1A to 100A. Triggers when current exceeds the set limit.
  • OPP (Over-Power Protection): Configurable from 0.01W to 9.99KW. Triggers when power consumption exceeds the set limit.
  • LOP (Low-Voltagای تحفظ): Configurable from 0.01V to 90V. Triggers when voltage drops below the set limit.
  • OAH (Over-Charge Protection): Configurable from 0.01AH to 9999AH. Triggers when accumulated charge exceeds the set limit.
  • OFT (Over-Time Protection): Configurable from 1 minute to 99 hours 59 minutes. Triggers when operation time exceeds the set limit.

When a protection limit is reached, the meter can activate an external relay (if connected) to disconnect the load or charging source.

دیگر افعال

  • AH Power Off Memorized Function: Retains accumulated Amp-Hour data even after power loss.
  • LCD Screen Auto/Manual Switch Off: The display can be configured to turn off automatically after a period of inactivity or can be manually toggled.

دیکھ بھال

The DROK Bidirectional Volt Amp Meter is designed for durability and requires minimal maintenance.

  • صفائی: ڈسپلے کو صاف کرنے کے لیے نرم، خشک کپڑا استعمال کریں اور casinجی کھرچنے والے کلینر یا سالوینٹس سے پرہیز کریں۔
  • ماحولیاتی حالات: Operate the meter within its specified temperature and humidity ranges. Avoid exposure to extreme temperatures, direct sunlight, or moisture.
  • وائرنگ معائنہ: وقتاً فوقتاً تمام وائرنگ کنکشن کی جکڑن اور پہننے یا سنکنرن کی علامات کے لیے چیک کریں۔

خرابی کا سراغ لگانا

  • کوئی ڈسپلے/پاور نہیں:
    • Check power connections to the Hall sensor.
    • بجلی کی فراہمی والیوم کو یقینی بنائیںtage 10-60V کی حد کے اندر ہے۔
    • Verify the jumper cap setting for self-powered or external power mode.
    • Check the shielding wire connection between the sensor and the display.
  • Incorrect Current Readings:
    • Ensure the load wire passes correctly through the Hall sensor's central hole.
    • Verify the direction of current flow relative to the arrow on the Hall sensor.
    • Perform a current calibration as described in the "Operating Instructions" section.
    • If monitoring both charging and discharging, ensure only the main battery wire (or the wire carrying the net current) passes through the sensor. Incorrect wiring can lead to inaccurate bidirectional readings.
  • غلط والیومtagای ریڈنگز:
    • والیم چیک کریںtage connections to the Hall sensor.
    • یقینی بنائیں کہ کنکشن محفوظ اور سنکنرن سے پاک ہیں۔
  • Protection Function Not Triggering:
    • Verify that the protection limits are set correctly in the meter's menu.
    • Ensure the external relay (if used) is correctly wired and functional.

وارنٹی اور سپورٹ

Specific warranty information for the DROK Bidirectional Volt Amp Meter (Model 200536FBA) is not provided in this manual. For warranty claims, technical support, or further assistance, please refer to the product packaging, the seller's website, or contact DROK customer service directly.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.