This manual provides detailed instructions for the proper use and maintenance of your EVTSCAN Soil Tester. Please read this manual thoroughly before operating the device to ensure accurate measurements and prolonged product life. This device is designed for measuring soil temperature, air temperature, air humidity, and illumination levels in various environments such as plants, gardens, lawns, and farms.

پروڈکٹ ختمview

The EVTSCAN Soil Tester is a portable device designed for quick and accurate environmental measurements. It features a clear display, easy-to-use buttons, and a durable probe.

سامنے والا view of the EVTSCAN Soil Tester, showing the display, buttons, and probe.

شکل 1: سامنے view of the EVTSCAN Soil Tester.

اہم خصوصیات:

  • استعمال میں آسان: Obtain test results quickly by inserting the probe into the soil.
  • درست پیمائش: Designed for precise readings of environmental conditions.
  • Data Lock Function: A dedicated HOLD button allows for convenient data viewing
  • پورٹیبل ڈیزائن: Compact and lightweight for easy transport and use in various locations.
  • ورسٹائل ایپلی کیشن: Suitable for family plants, gardens, lawns, and farms.

سیٹ اپ

بیٹری کی تنصیب:

  1. ڈیوائس کے پچھلے حصے میں بیٹری کے ٹوکرے کا پتہ لگائیں۔
  2. بیٹری کے ٹوکری کا احاطہ کھولیں۔
  3. Remove any packaging from the included 9V 6F22 dry battery.
  4. درست قطبیت کو یقینی بناتے ہوئے 9V بیٹری داخل کریں۔
  5. بیٹری کے کمپارٹمنٹ کور کو محفوظ طریقے سے بند کریں۔
پیچھے view of the EVTSCAN Soil Tester, showing the battery compartment.

شکل 2: بیٹری کے ڈبے کا مقام۔

Note: The device will not power on until the battery is correctly installed and any protective film is removed from the battery terminals.

آپریٹنگ ہدایات

ڈیوائس کنٹرولز:

Close-up of the EVTSCAN Soil Tester's control buttons: ON/OFF, C/F, and HOLD.

Figure 3: Control buttons on the EVTSCAN Soil Tester.

  • آن/آف بٹن:
    • Short press to turn the device on.
    • Long press for 3 seconds to turn the device off.
    • The device will automatically turn off after 15 minutes of inactivity to conserve battery life.
  • ℃/℉ بٹن:
    • Press this button to switch the temperature unit between Celsius (℃) and Fahrenheit (℉).
  • ہولڈ بٹن:
    • Press this button to lock the current readings on the display. This is useful for recording data.
    • Press again to release the data lock and resume live readings.

پیمائش کرنا:

  1. Turn on the device by short pressing the آن/آف بٹن
  2. Insert the metal probe into the soil to approximately 2/3 of its length (about 14-15 cm or 5.5-6 inches). Ensure the probe is fully inserted into the root zone for accurate soil readings.
  3. Position the device to face the sun for accurate illumination readings.
  4. Wait a few moments for the readings to stabilize on the display. The display will show soil temperature, air temperature, air humidity, and illumination.
  5. اگر چاہیں تو دبائیں۔ پکڑو button to lock the displayed data for easier recording.
  6. After use, gently remove the probe from the soil.
EVTSCAN Soil Tester with probe length indicated as 22cm / 8.7in.

Figure 4: Probe length and recommended insertion depth.

Close-up of the EVTSCAN Soil Tester display showing readings for soil, air temperature, air humidity, and light.

شکل 5: سابقample of readings on the display.

وضاحتیں

پیرامیٹرقدر
Soil Temperature Range-20 ℃ to +70 ℃ (-4 ℉ to +158 ℉)
ہوا کے درجہ حرارت کی حد-10 ℃ to +50 ℃ (+14 ℉ to +122 ℉)
ہوا میں نمی کی حد20% سے 99% RH
بجلی کی فراہمی1 x 9V 6F22 dry battery (280mAh)
تحقیقات کی لمبائیApprox. 22 cm / 8.7 in
شے کا وزن7.7 اونس
کارخانہ دارEVTSCAN
بنیادی افعالAir temperature, Air humidity, Illumination display, ℃/℉ temperature switching, Data retention, Comfort display

دیکھ بھال

  • صفائی: After each use, wipe the metal probe clean with a damp cloth to remove any soil residue. Do not immerse the main body of the device in water.
  • ذخیرہ: Store the soil tester in a dry, cool place away from direct sunlight and extreme temperatures.
  • بیٹری کی تبدیلی: If the display becomes dim or the device does not power on, replace the 9V battery. Ensure proper disposal of old batteries according to local regulations.
  • اثر سے بچیں: Handle the device with care to prevent damage to the probe or internal components.

خرابی کا سراغ لگانا

مسئلہممکنہ وجہحل
ڈیوائس آن نہیں ہوتی۔بیٹری ختم ہو چکی ہے یا غلط طریقے سے انسٹال ہوئی ہے۔Check battery installation; replace with a new 9V battery if necessary.
غلط یا اتار چڑھاؤ والی ریڈنگ۔Probe is not fully inserted or is dirty; soil is too dry or too wet.Ensure probe is inserted to 2/3 depth; clean probe thoroughly; ensure soil has adequate moisture for accurate readings.
ڈسپلے مدھم ہے۔کم بیٹری۔9V بیٹری کو تبدیل کریں۔
Automatic shutdown occurs too quickly.Normal operation (15 minutes of inactivity).This is a power-saving feature. Turn the device back on if further use is required.