This manual provides essential information for the safe and efficient installation, operation, and maintenance of your EARU Electric 3-Phase Auto Transfer Switch (ATS) - 440V 63A. Please read this manual thoroughly before installation and operation to ensure proper functionality and to prevent damage or injury.

The ATS is designed to provide uninterrupted power by automatically transferring loads between phases in a three-phase supply system. It features intelligent monitoring and protection against phase failure, over/under voltage, and overcurrent conditions, ensuring the stability and safety of connected equipment.

2. حفاظتی معلومات

انتباہ: بجلی کے جھٹکے کا خطرہ۔ تنصیب اور سروسنگ صرف اہل اہلکاروں کے ذریعہ انجام دی جانی چاہئے۔

  • Always disconnect power before installing or servicing the ATS.
  • یقینی بنائیں کہ تمام وائرنگ مقامی اور قومی برقی کوڈز کی تعمیل کرتی ہے۔
  • درست جلد کی تصدیق کریں۔tage and current ratings before connecting the device.
  • اگر آلہ خراب نظر آتا ہے تو اسے نہ چلائیں۔
  • بچوں کو بجلی کے آلات سے دور رکھیں۔

3. پروڈکٹ ختمview

The EARU Electric 3-Phase ATS is an intelligent device that continuously monitors your three-phase power supply. It automatically switches single-phase loads to a healthy phase in case of a phase failure or imbalance, ensuring continuous operation of critical equipment.

3.1. پیکیج کے مشمولات

  • 1 x EARU Electric 3-Phase Auto Transfer Switch (ATS)

3.2. Front Panel and Indicators

Front panel of EARU Electric 3-Phase ATS with digital display and control buttons

تصویر کی تفصیل: The front panel of the ATS features a digital display showing voltage for L1, L2, L3 phases and current for L1. Below the display are indicators for Power, Over-voltage (>V), Under-voltage (<V), and Over-current (>I). Control buttons include 'SET' (Menu key), 'Digit+/Up', 'Digit-/Down', and 'Manual ON/OFF' (Power button).

The digital display provides real-time voltage readings for each phase (L1, L2, L3) and the current for L1. Status indicators alert you to the operational state and any detected faults:

  • طاقت: Output indication.
  • >V: زیادہ جلدtagای اشارہ.
  • <V: زیر جلدtagای اشارہ.
  • >میں: Over-current indication.

Control buttons allow for parameter settings and manual operation:

  • سیٹ: Menu key for accessing settings.
  • Digit+/Up: Increases value or navigates up in menus.
  • Digit-/Down: Decreases value or navigates down in menus.
  • دستی آن/آف: Power button for manual control.

4. سیٹ اپ اور انسٹالیشن

The ATS is designed for standard DIN rail mounting. Ensure sufficient space for ventilation and wiring connections.

4.1. وائرنگ ڈایاگرام

Wiring diagram for EARU Electric 3-Phase ATS showing input and output connections

تصویر کی تفصیل: A detailed wiring diagram illustrates the connection points for the ATS. The top terminals are labeled 'IN' with connections for N, L1, L2, L3. The bottom terminals are labeled 'OUT' with connections for N and L1. The diagram shows how to connect the three-phase input to the ATS and how a single-phase load (L1 and N) is connected to the output, with internal connections for phase monitoring and switching.

Follow the wiring diagram carefully. Incorrect wiring can lead to device malfunction or electrical hazards.

  • Connect the incoming three-phase power supply (N, L1, L2, L3) to the 'IN' terminals.
  • Connect the single-phase load (N, L1) to the 'OUT' terminals. The ATS will manage the phase transfer for the L1 output.
  • Ensure all connections are secure and tightened to prevent loose contacts and overheating.

4.2 ابتدائی پاور اپ

After completing the wiring, restore power to the system. The ATS will power on and begin monitoring the phases. The digital display will show the current voltage readings for each phase. If all phases are stable and within acceptable limits, the ATS will provide power to the output.

5. آپریٹنگ ہدایات

The ATS operates automatically, but you can adjust its protection parameters to suit your specific requirements.

5.1. ڈسپلے اور اشارے کو سمجھنا

The digital display continuously shows the real-time voltage of each phase (L1, L2, L3) and the current on L1. The indicator lights provide quick visual feedback on the device's status and any detected anomalies.

Close-up of EARU Electric 3-Phase ATS digital display showing voltagای اور موجودہ ریڈنگز

تصویر کی تفصیل: ایک قریبی اپ view of the ATS digital display. It shows '220V' for L1, L2, and L3, and '63.0A' for L1 current. Below these readings are small indicator icons for Power, >V (Over-voltage), <V (Under-voltage), and >I (Over-current).

5.2. Adjusting Protection Parameters

Use the 'SET' button to enter the parameter setting mode. Use the 'Digit+/Up' and 'Digit-/Down' buttons to navigate through settings and adjust values. Press 'SET' again to confirm and save changes.

Adjustable Protection Parameters
پیرامیٹرترتیب کی حدپہلے سے طے شدہ ترتیب
Over Current Protection Setting Range1-63A/100A30A
Continuous Over Current Protection Times0-20 بارآف
جلد سے زیادہtage Protection Setting Range230-300V270V
جلد سے زیادہtage Protection Recover Setting Range225-295V265V
جلد کے تحتtage Protection Setting Range140-210V170V
جلد کے تحتtage Protection Recover Setting Range145-215V175V
والیومtage & Current Protection Recover Delay1-500 سیکنڈ30s

5.3. Automatic Phase Transfer

The ATS automatically monitors the three input phases (L1, L2, L3). If a phase failure or significant voltage imbalance (over/under voltage) is detected on the currently supplying phase, the device will automatically transfer the single-phase output load to a healthy, stable phase within the same supply. This process is designed to be seamless and rapid, minimizing power interruption to connected equipment.

5.4. Automatic Recovery

Once the primary phase recovers and stabilizes, the ATS will intelligently switch the load back to the primary source, ensuring optimal power distribution and preventing equipment damage from unstable power. The recovery delay can be configured as per your operational needs.

6 دیکھ بھال

The EARU Electric ATS is designed for minimal maintenance. However, periodic checks are recommended to ensure optimal performance and longevity.

  • صفائی: Keep the device clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
  • کنکشن چیکس: وقتاً فوقتاً تمام وائرنگ کنکشن کا معائنہ کریں تاکہ یہ یقینی بنایا جا سکے کہ وہ سخت اور سنکنرن سے پاک ہیں۔
  • ماحولیاتی حالات: یقینی بنائیں کہ آپریٹنگ ماحول مخصوص درجہ حرارت اور نمی کی حدود کے اندر رہتا ہے۔

7 خرابیوں کا سراغ لگانا

If you encounter issues with your ATS, refer to the following common problems and solutions:

مشکلات کا حل گائیڈ
مسئلہممکنہ وجہحل
کوئی پاور آؤٹ پٹ نہیں۔No input power; all phases unstable; device in fault state.Check incoming power supply. Verify all phases are stable. Check fault indicators.
">V" or "<V" indicator litزیادہ جلدtage یا زیر جلدtage detected on a phase.ان پٹ والیوم چیک کریں۔tage stability. The ATS will automatically transfer if another phase is healthy.
">I" indicator litOver-current detected on the output.Reduce load on the output. Check for short circuits in the connected equipment.
Device not transferring phasesNo healthy alternative phase available; transfer delay setting too long.Ensure at least one healthy phase is present. Check and adjust the transfer delay settings.
ڈیجیٹل ڈسپلے کام نہیں کر رہا ہے۔No power to the device; internal fault.Check power supply. If power is present and display is off, contact support.

For issues not covered here, please contact EARU customer support.

8. وضاحتیں

Detailed specifications and dimensions of EARU Electric 3-Phase ATS

تصویر کی تفصیل: This image displays the physical dimensions of the ATS (90mm width, 96mm height, 66mm depth) and a table of detailed technical specifications, including current rating, voltage, frequency, and various protection setting ranges.

فیچرتفصیل
برانڈای آر یو
ماڈل نمبرEARU-1012
آپریشن موڈکبھی کبھی
موجودہ درجہ بندی63 Amps
آپریٹنگ والیومtage440 Volts (AC 3*220V (N-L1/L2/L3))
شرح شدہ تعدد50/60Hz
رابطہ کی قسمعام طور پر کھولیں۔
کنیکٹر کی قسمStandard DIN rail 63A
سرکٹ کی قسم4 طرفہ
رابطہ کا موادتانبا
Over Current Protection Setting Range1-63A/100A (Default 30A)
Continuous Over Current Protection Times0-20 Times (Default OFF)
جلد سے زیادہtage Protection Setting Range230-300V (Default 270V)
جلد سے زیادہtage Protection Recover Setting Range225-295V (Default 265V)
جلد کے تحتtage Protection Setting Range140-210V (Default 170V)
جلد کے تحتtage Protection Recover Setting Range145-215V (Default 175V)
والیومtage & Current Protection Recover Delay1-500s (Default 30s)
شے کا وزن450 گرام
پیکیج کے طول و عرض15 x 15 x 15 سینٹی میٹر
اصل ملکانڈیا

9. وارنٹی اور سپورٹ

9.1. وارنٹی کی معلومات

The EARU Electric 3-Phase Auto Transfer Switch (ATS) comes with a 1 سالہ مینوفیکچرر کی وارنٹی خریداری کی تاریخ سے. یہ وارنٹی عام استعمال کے تحت مواد اور کاریگری میں نقائص کا احاطہ کرتی ہے۔ یہ غلط تنصیب، غلط استعمال، حادثات، یا غیر مجاز ترمیم کی وجہ سے ہونے والے نقصان کا احاطہ نہیں کرتا ہے۔