The ICM Controls ICM203 is a universal voltage delay on break timer designed to protect compressors from damage caused by rapid short cycling. This anti-short cycle relay ensures that the compressor remains off for a set period after power interruption, allowing system pressures to equalize before restarting. It operates across a wide voltage range and features an adjustable delay setting.

سامنے والا view of the ICM Controls ICM203 Delay on Break Timer, showing the adjustable dial, wiring terminals, and product labeling.
2. کلیدی خصوصیات
- کمپریسر تحفظ: Prevents damage from rapid short cycling with built-in lockout safety.
- سایڈست تاخیر: Set custom delay time from 1.8 to 600 seconds for flexible system control.
- وسیع جلدtagای رینج: Operates on 18–240 VAC, suitable for a broad range of HVAC and refrigeration applications.
- سادہ تنصیب: Easy 2-wire hookup for quick and reliable setup.
- پائیدار اور قابل اعتماد: Solid-state design ensures long-lasting performance in demanding environments.
3. وضاحتیں
| تفصیلات | قدر |
|---|---|
| ماڈل نمبر | آئی سی ایم 203 |
| ان پٹ جلدtage | 18-240 VAC |
| سایڈست تاخیر | 1.8–600 Seconds (0.03–10 Minutes) |
| لوڈ کرنٹ | 1.5 Amp زیادہ سے زیادہ |
| مصنوعات کے طول و عرض | 2"D x 2"W x 1.25"H (5.08 سینٹی میٹر x 5.08 سینٹی میٹر x 3.18 سینٹی میٹر) |
| شے کا وزن | 1.6 اونس (45.36 گرام) |
| ترتیبات کی تعداد | 1 (adjustable dial) |
| کارخانہ دار | ICM Controls |

طرف view of the ICM Controls ICM203 Delay on Break Timer, illustrating its depth and mounting hole.
4. تنصیب
حفاظتی انتباہ: Installation of this device involves working with electrical components and potentially high voltages. To prevent electric shock or damage to equipment, installation should only be performed by a qualified professional or person familiar with HVAC electrical systems. Always disconnect power to the unit before beginning installation.

Close-up of the ICM Controls ICM203 Delay on Break Timer being wired, showing the red jumper wire for 120/240 VAC selection.
عام تنصیب کے مراحل:
- پاور منقطع کریں: Ensure all power to the HVAC unit or compressor is completely disconnected at the circuit breaker.
- Locate Compressor Contactor: Identify the low voltage control circuit for the compressor contactor.
- وائر کنکشن: The ICM203 features a simple 2-wire hookup. Connect the two wires of the ICM203 in series with the 24 VAC control circuit that energizes the compressor contactor coil. This means the timer will interrupt the control voltagای کانٹیکٹر کو۔
- والیومtage Selection (if applicable): The ICM203 is universal voltage. For 120/240 VAC applications, ensure the red jumper wire is correctly configured or cut as indicated on the device label, if necessary for your specific voltage. Refer to the device's printed instructions for precise wiring diagrams.
- چڑھنا: Securely mount the ICM203 in a suitable location within the control panel or near the compressor, ensuring it is protected from environmental elements.
- بجلی کی بحالی: Once wiring is complete and verified, restore power to the unit.

Hands installing the ICM Controls ICM203 Delay on Break Timer into an HVAC unit, showing wiring connections.
This device requires installation by a professional or qualified person due to electrical safety considerations.
5. آپریشن
The ICM203 operates automatically once installed. Its primary function is to enforce a delay before the compressor can restart after a power interruption or a call for cooling is removed and then immediately reapplied. This delay protects the compressor from short cycling.
Adjusting the Delay Time:
The delay time is adjustable using the red dial located on the front of the unit. The dial is marked in minutes, typically ranging from 0.03 minutes (approximately 1.8 seconds) to 10 minutes (600 seconds). To adjust the delay:
- Locate the Dial: Find the red adjustment dial on the face of the ICM203.
- Rotate to Desired Setting: Carefully rotate the dial using a small screwdriver or similar tool to align the indicator with the desired delay time in minutes. Common settings are often between 3 to 5 minutes to allow sufficient pressure equalization.
- آپریشن کی تصدیق کریں: After setting, observe the system's behavior to ensure the delay functions as intended before the compressor restarts.
6 دیکھ بھال
The ICM Controls ICM203 Delay on Break Timer is a solid-state device designed for reliable, maintenance-free operation. No routine maintenance is required. Periodically, ensure that electrical connections remain secure and free from corrosion. If the unit appears damaged or is not functioning correctly, it should be inspected by a qualified technician.
7 خرابیوں کا سراغ لگانا
If the ICM203 is not functioning as expected, consider the following:
- کوئی تاخیر نہیں: Verify the dial is set to a non-zero delay time. Ensure the unit is correctly wired in series with the compressor contactor's control circuit.
- کمپریسر شروع نہیں ہو رہا ہے: Check for proper power supply to the ICM203. Ensure all wiring connections are secure. If the delay period has elapsed and the compressor still does not start, investigate other components of the HVAC system.
- Incorrect Delay Time: Re-adjust the dial to the desired setting. Note that the adjustment at the very low end of the scale can be sensitive.
- Unit Damage: Visually inspect the ICM203 for any signs of physical damage or burning. If damaged, replace the unit.
مستقل مسائل کے لیے، ایک مستند HVAC ٹیکنیشن سے مشورہ کرنے کی سفارش کی جاتی ہے۔
8. وارنٹی کی معلومات
ICM Controls products are known for their quality and reliability. The ICM203 is manufactured in the USA and comes with a warranty designed to ensure customer satisfaction. For specific details regarding the warranty period and terms, please refer to the official ICM Controls webسائٹ یا تکنیکی مدد سے رابطہ کریں۔
ICM Controls products are proudly Made in America and backed by a strong industry warranty.
9. تکنیکی معاونت
For technical assistance, installation questions, or troubleshooting support, please contact ICM Controls Technical Support.
Contact ICM Controls Technical Support for assistance.
فون: 1-800-365-5525, Option 8
گھنٹے: Monday - Friday, 8:00 AM - 5:00 PM EST