This manual provides essential instructions for the safe installation, operation, and maintenance of your Gira 010600 10600 Standard Switch. Please read this manual thoroughly before installation and retain it for future reference. This product is designed for intelligent building technology applications.

حفاظتی معلومات

WARNING: Installation must be carried out by a qualified electrician in accordance with national wiring regulations and local safety standards. Always disconnect the main power supply before commencing any electrical work.

  • Ensure the power supply is completely off before installation or maintenance.
  • ڈی میں انسٹال نہ کریں۔amp or wet conditions unless the product is specifically rated for such environments.
  • Verify correct wiring connections to prevent electrical hazards.
  • This switch is rated for 250V. Do not exceed specified voltage.

سیٹ اپ اور انسٹالیشن

The Gira 010600 10600 Standard Switch is designed for flush-mounted installation. Ensure you have the necessary tools and a suitable flush-mounted box.

جزو ختم۔view

Gira 010600 Standard Switch Mechanism

تصویر 1: پیچھے view of the Gira 010600 switch mechanism, showing terminals and mounting points. The transparent housing allows for visual inspection of internal components.

وائرنگ کی ہدایات

Refer to the following diagrams for correct wiring. The Gira 010600 is compatible with Gira 0106 00 devices and supports various switching configurations.

Wiring Diagram for Gira 010600 Cross Switch

تصویر 2: Wiring diagram for a cross switch configuration (Kreuzschalter). This diagram illustrates the connections for AC 230V~, including live (L) and neutral (N) lines, and the lamp connection. This setup is used for controlling a light from three or more locations.

Wiring Diagram for Gira 010600 Universal Switch

تصویر 3: Wiring diagram for a universal switch configuration (Universal Aus-Wechselschalter). This diagram shows connections for AC 230V~ and a lamp, suitable for controlling a light from one or two locations. It includes connections for two 0106 00 switches and one 0107 00 switch, demonstrating a multi-point control setup.

  1. پاور منقطع کریں: Turn off the main power supply at the circuit breaker before starting any work.
  2. تاریں تیار کریں: بجلی کے تاروں کے سروں سے تقریباً 10-12 ملی میٹر کی موصلیت کو ہٹا دیں۔
  3. تاروں کو جوڑیں: Following the appropriate wiring diagram (Figure 2 or Figure 3), insert the wires into the corresponding terminals on the switch mechanism. Ensure a secure connection. The switch is designed for 250V operation.
  4. ماؤنٹ سوئچ: Carefully place the switch mechanism into the flush-mounted box. Secure it using the screws provided with the box or switch.
  5. Attach Cover Plate: Install the decorative cover plate and rocker (not included with the mechanism) onto the switch.
  6. بجلی کی بحالی: ایک بار جب انسٹالیشن مکمل ہو جائے اور تمام کنکشن محفوظ ہو جائیں، سرکٹ بریکر پر بجلی بحال کریں۔

آپریٹنگ ہدایات

The Gira 010600 10600 Standard Switch operates as a conventional electrical switch.

  1. To turn on the connected electrical device (e.g., a light), press the rocker switch to the 'ON' position.
  2. To turn off the connected electrical device, press the rocker switch to the 'OFF' position.

In multi-point switching configurations (e.g., cross switch or universal switch setups), the state of the connected device can be toggled from any connected switch.

دیکھ بھال

The Gira 010600 10600 Standard Switch requires minimal maintenance.

  • صفائی: سوئچ کی سطح کو صاف کرنے کے لیے، نرمی سے اسے صاف کریں، ڈیamp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the transparent material.
  • معائنہ: Periodically check the switch for any signs of damage, loose connections, or discoloration. If any issues are observed, disconnect power and consult a qualified electrician.
  • صارف کے قابل خدمت حصے نہیں: The internal components of the switch are not user-serviceable. Do not attempt to open or repair the switch mechanism.

خرابی کا سراغ لگانا

If you encounter issues with your Gira 010600 10600 Standard Switch, refer to the following common problems and solutions:

مسئلہممکنہ وجہحل
Light/Device does not turn on.
  • سرکٹ کی طاقت نہیں ہے۔
  • ڈھیلا وائرنگ کنکشن۔
  • Faulty bulb/device.
  • غلط وائرنگ۔
  • سرکٹ بریکر چیک کریں۔
  • (With power off) Inspect and tighten connections.
  • Test with a known working bulb/device.
  • (With power off) Verify wiring against diagrams (Figure 2, Figure 3).
سوئچ ڈھیلا یا ڈوبتا ہوا محسوس ہوتا ہے۔
  • بڑھتے ہوئے پیچ ڈھیلے ہیں۔
  • Improper installation in the flush box.
  • (With power off) بڑھتے ہوئے پیچ کو سخت کریں۔
  • (With power off) Re-seat the switch mechanism properly.
سوئچ ٹچ کرنے کے لئے گرم ہے.
  • سرکٹ پر اوورلوڈ۔
  • Loose connection causing resistance.
  • ناقص سوئچ۔
  • Immediately disconnect power. Reduce load on the circuit.
  • (With power off) تمام کنکشن چیک کریں اور سخت کریں۔
  • If problem persists, replace the switch. Consult a qualified electrician.

If the problem persists after attempting these solutions, contact a qualified electrician or Gira customer support.

وضاحتیں

  • برانڈ: گیرا
  • ماڈل کا نام: 10600
  • ہم آہنگ آلات: Gira 0106 00
  • مواد: دھات
  • یونٹس کی تعداد: 1 کل
  • رنگ: شفاف
  • والیومtagای درجہ بندی: 250 وی
  • مینوفیکچرر: جیرا
  • UPC: 740439921339

سپورٹ اور وارنٹی

For technical support or warranty inquiries, please contact your local Gira distributor or visit the official Gira webسائٹ خریداری کے ثبوت کے طور پر اپنی خریداری کی رسید اپنے پاس رکھیں۔

Gira is committed to providing intelligent building technology solutions. For more information, visit www.gira.com.

متعلقہ دستاویزات - 10600

پریview Gira پروجیکٹ اسسٹنٹ (GPA) v6.0 ریلیز نوٹس
Gira پروجیکٹ اسسٹنٹ (GPA) ورژن 6.0 کے لیے تفصیلی ریلیز نوٹس، جس میں نظام کی ضروریات، تنصیب، ہم آہنگ فرم ویئر، نئی خصوصیات، اصلاح، بگ فکسز، اور Gira سمارٹ ہوم اور بلڈنگ آٹومیشن سسٹمز کے لیے معلوم مسائل شامل ہیں۔
پریview Gira Projekt Assistent (GPA) Release Notes Version 6.0
Release notes for Gira Projekt Assistent (GPA) software version 6.0, detailing system requirements, new features, optimizations, bug fixes, and important usage guidelines for Gira smart home and building automation systems.
پریview Gira Smart Home: Comfort, Veiligheid en Energiebesparing
Ontdek de Gira Smart Home-oplossingen voor een comfortabel, veilig en energiezuinig huis. Ervaar intelligente technologie en tijdloos design van Gira, gebaseerd op de KNX-standaard.
پریview Gira Project Assistant (GPA) 6.0 Release Notes and Guide
Detailed release notes for Gira Project Assistant (GPA) version 6.0, covering system requirements, supported devices, new features, optimizations, bug fixes, and important guidance for smart home system configuration.
پریview Gira پروجیکٹ اسسٹنٹ (GPA) 6.0: نیا فنکشنز اور اپڈیٹس
Ontdek de nieuwste versie van Gira پروجیکٹ اسسٹنٹ (GPA) 6.0۔ Leer over systeemvereisten, ondersteunde apparaten, nieuwe functions, optimalisaties en belangrijke updates voor uw Gira smart home projecten.
پریview Gira HomeServer Client Start-up Guide for Gira G1 (2nd Gen)
Step-by-step instructions for setting up and configuring the Gira G1 (2nd generation) client with Gira HomeServer using GPA and QuadConfig. Covers standard and room operating device modes.