1. تعارف
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the TCS NGV1011-0400 Intercom Accessory Control Unit. Please read this manual thoroughly before attempting to install or operate the device. Retain this document for future reference.
2. حفاظتی معلومات
انتباہ: Electrical shock hazard. Installation and servicing must be performed by qualified personnel only. Disconnect power before installation or maintenance.
- اس بات کو یقینی بنائیں کہ تنصیب کے دوران تمام مقامی اور قومی برقی کوڈز کی پیروی کی جائے۔
- یونٹ کو نمی یا انتہائی درجہ حرارت کے سامنے نہ رکھیں۔
- درست جلد کی تصدیق کریں۔tagبجلی سے منسلک ہونے سے پہلے ای اور موجودہ درجہ بندی۔
- Always use appropriate tools and personal protective equipment.
3. پروڈکٹ ختمview
The TCS NGV1011-0400 is an accessory control unit designed for intercom systems, typically used with door stations. It functions as a power supply and control interface, converting AC input to DC output for system components.

Figure 1: TCS NGV1011-0400 Intercom Accessory Control Unit. This image displays the TCS NGV1011-0400 intercom accessory control unit. The front panel features the TCS logo, model number NGV1011-0400, and CE marking. Terminal blocks are visible at the top and bottom for electrical connections. The label indicates an output voltage of 26 V DC / 2.5 A and AC input terminals L, N, PE.
اہم خصوصیات:
- Designed for door station applications.
- ان پٹ جلدtage: 230 V AC۔
- آؤٹ پٹ والیمtage: 26 V DC at 2.5 A.
- Integrated terminal blocks for secure wiring.
4. سیٹ اپ اور انسٹالیشن
Before beginning installation, ensure the main power supply is disconnected. The unit is designed for DIN rail mounting within an electrical enclosure.
4.1 وائرنگ کنکشن:
Refer to the product label and Figure 1 for terminal identification.
- AC Input (Terminals L, N, PE): Connect the 230 V AC mains power supply to these terminals.
- L (Line): لائیو تار سے جڑیں۔
- N (غیر جانبدار): غیر جانبدار تار سے جڑیں۔
- PE (Protective Earth): Connect to the protective earth ground.
- DC Output (Terminals 29, 31): These terminals provide the 26 V DC / 2.5 A output for the intercom system components.
- ٹرمینل 29: Connect to the negative (-) DC input of the intercom component.
- ٹرمینل 31: Connect to the positive (+) DC input of the intercom component.
- Control Output (Terminal 36): This terminal is typically used for control signals, such as activating a door opener or a light. Consult your intercom system's specific wiring diagram for its function.
After all connections are made, double-check wiring for correctness and secureness before restoring power.
5. آپریٹنگ ہدایات
The TCS NGV1011-0400 operates automatically once correctly installed and powered. It provides the necessary power and control signals to the connected intercom system. There are no user-adjustable controls on the unit itself.
- پاور آن: Once AC power is supplied to the L, N, PE terminals, the unit will power on and provide 26 V DC output.
- سسٹم انٹیگریشن: The functionality of the NGV1011-0400 is integrated with the overall intercom system. Refer to the manual of your specific intercom system for operational details.
6 دیکھ بھال
The TCS NGV1011-0400 is designed for minimal maintenance. Regular inspections are recommended to ensure optimal performance.
- صفائی: Disconnect power before cleaning. Use a soft, dry cloth to wipe the exterior of the unit. Do not use liquid cleaners or solvents.
- معائنہ: Periodically check all wiring connections for tightness and signs of wear or damage. Ensure the unit is free from dust accumulation, which can impede cooling.
- ماحولیاتی حالات: یقینی بنائیں کہ آپریٹنگ ماحول مخصوص درجہ حرارت اور نمی کی حدود میں رہے۔
7 خرابیوں کا سراغ لگانا
If the intercom system is not functioning correctly, consider the following troubleshooting steps related to the NGV1011-0400 unit:
- پاور آؤٹ پٹ نہیں:
- Verify that the 230 V AC mains power supply is active and correctly connected to terminals L, N, and PE.
- Check for tripped circuit breakers or blown fuses in the main electrical panel.
- Ensure all DC output connections (Terminals 29, 31) are secure and correctly polarized.
- وقفے وقفے سے آپریشن:
- ڈھیلے کنکشن یا خراب موصلیت کے لیے تمام وائرنگ کا معائنہ کریں۔
- Ensure the unit is not overheating due to inadequate ventilation or excessive load.
- If problems persist after performing these checks, contact qualified service personnel. Do not attempt to repair the unit yourself.
8. وضاحتیں
| پیرامیٹر | قدر |
|---|---|
| برانڈ | ٹی سی ایس |
| ماڈل نمبر | NGV1011-0400 |
| درخواست | Door Station Accessory / Intercom Control Unit |
| AC ان پٹ والیومtage | 230 وی |
| تعدد | 50 Hz |
| ڈی سی آؤٹ پٹ والیمtagای / کرنٹ | 26 وی ڈی سی / 2.5،XNUMX اے |
| شے کا وزن | 200 گرام |
9. وارنٹی کی معلومات
Warranty information for the TCS NGV1011-0400 is not provided in the available product data. Please refer to your purchase documentation or contact your retailer for details regarding warranty coverage.
10. سپورٹ
Specific support contact information is not provided in the available product data. For technical assistance or service, please contact the retailer where the product was purchased or visit the official TCS website for general support resources.