تعارف
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump. Please read this manual thoroughly before operating the pump and retain it for future reference.
The Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump is designed for deeper vacuum draw, pulling vacuum down to 75 microns. Its precision-machined one-stage pump effectively removes moisture from air conditioning systems, preparing them for safe refrigerant addition. This pump is ideal for automotive air conditioning, HVAC work, and other applications requiring high vacuum pull from a compact unit.
اہم حفاظتی معلومات
Always observe basic safety precautions when using this product to reduce the risk of personal injury and damage to equipment.
- استعمال سے پہلے تمام ہدایات پڑھیں۔
- حفاظتی شیشے اور دستانے سمیت مناسب ذاتی حفاظتی سامان (PPE) پہنیں۔
- اس بات کو یقینی بنائیں کہ کام کی جگہ اچھی طرح سے ہوادار ہے۔
- گیلے حالات میں پمپ کو نہ چلائیں اور نہ ہی اسے بارش میں بے نقاب کریں۔
- کسی بھی دیکھ بھال یا خدمت کو انجام دینے سے پہلے بجلی منقطع کریں۔
- Use only with specified refrigerants (R134A, R12, R22).
سیٹ اپ
Before initial operation, ensure the vacuum pump is placed on a stable, level surface. Check the oil level and fill if necessary with appropriate vacuum pump oil.
Initial Oil Fill/Check
- Locate the oil fill cap and sight glass on the pump.
- Unscrew the oil fill cap.
- Pour vacuum pump oil into the fill port until the oil level is visible in the sight glass, reaching the indicated fill line. Do not overfill.
- تیل بھرنے کی ٹوپی کو محفوظ طریقے سے تبدیل کریں۔
Connecting to an HVAC System
The pump features dual ports for R134A and R12/R22 systems. Use appropriate manifold gauges and hoses for connection.

تصویر 1: The Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump connected to an HVAC system. The image shows the vacuum pump on a wooden deck, connected via yellow and blue hoses to a manifold gauge set. The manifold gauge set is then connected to an outdoor HVAC unit. This setup illustrates a typical vacuuming process for an air conditioning system.
- Ensure all valves on the manifold gauge set are closed.
- Connect the appropriate vacuum hose from the manifold gauge set to the vacuum pump's inlet port.
- Connect the manifold gauge set to the service ports of the HVAC system.
- تصدیق کریں کہ لیک ہونے سے بچنے کے لیے تمام کنکشن سخت ہیں۔
آپریٹنگ ہدایات
Follow these steps for proper operation of the vacuum pump to evacuate an HVAC system.
- With the pump connected to the system and manifold gauges, open the manifold gauge valves to the system.
- Plug the vacuum pump into a grounded electrical outlet.
- Turn on the vacuum pump. The pump will begin to pull a vacuum on the system.
- Monitor the vacuum gauge on your manifold set. Allow the pump to run until the desired vacuum level (e.g., 75 microns or lower) is achieved and held steady for a specified period (e.g., 15-30 minutes) to ensure all moisture is removed.
- Once the desired vacuum is reached, close the manifold gauge valves to isolate the system from the pump.
- Turn off the vacuum pump and then disconnect it from the manifold gauges.
- Proceed with refrigerant charging as per HVAC system manufacturer's instructions.
دیکھ بھال
باقاعدگی سے دیکھ بھال آپ کے ویکیوم پمپ کی لمبی عمر اور بہترین کارکردگی کو یقینی بناتی ہے۔
تیل کی تبدیلی
Vacuum pump oil should be changed frequently, especially after each use on a contaminated system or when the oil appears cloudy or discolored. Contaminated oil reduces the pump's ability to pull a deep vacuum.
- Ensure the pump is off and unplugged.
- آئل ڈرین پلگ کے نیچے ایک مناسب کنٹینر رکھیں۔
- Remove the oil drain plug and allow all old oil to drain completely.
- آئل ڈرین پلگ کو محفوظ طریقے سے تبدیل کریں۔
- Refill with new, clean vacuum pump oil as described in the "Initial Oil Fill/Check" section.
عمومی صفائی
Keep the exterior of the pump clean and free of debris. Do not use harsh chemicals or solvents that could damage the housing.
خرابی کا سراغ لگانا
This section addresses common issues you might encounter with your vacuum pump.
| مسئلہ | ممکنہ وجہ | حل |
|---|---|---|
| پمپ شروع نہیں ہوتا ہے۔ | No power; Thermal overload tripped; Motor fault. | Check power connection and outlet; Allow pump to cool down; Consult qualified technician. |
| Pump not pulling sufficient vacuum | Low or contaminated oil; Leaks in system/hoses; Clogged inlet filter. | Change oil; Check all connections for leaks; Clean/replace inlet filter. |
| ضرورت سے زیادہ شور / کمپن | Low oil level; Damaged internal components. | Check and add oil; Contact customer support for service. |
وضاحتیں
Key technical specifications for the Pittsburgh 2.5 CFM 1/6 HP One Stage Vacuum Pump:
- درخواست: R134A, R12, R22 refrigerant
- بہاؤ کی شرح: 2.5 CFM
- Horsepower (hp): 1 / 6 HP
- زیادہ سے زیادہ ویکیوم: 75 مائکرون (10 پاسکل)
- مصنوعات کی اونچائی: 9 انچ
- مصنوعات کی لمبائی: 11-1/4 میں
- مصنوعات کی چوڑائی: 4-3/4 میں
- وزن: 18.25 پونڈ
- دھاگے کا سائز: 1/4 in. SAE & 1/2 in.
- ہاؤسنگ مواد: Durable die cast aluminum
- تحفظ: Thermal and current overload protection
وارنٹی اور سپورٹ
وارنٹی کی معلومات یا تکنیکی مدد کے لیے، براہ کرم صنعت کار کے اہلکار سے رجوع کریں۔ webسائٹ یا ان کے کسٹمر سروس ڈیپارٹمنٹ سے رابطہ کریں۔ وارنٹی کے دعووں کے لیے اپنی خریداری کی رسید اپنے پاس رکھیں۔
مینوفیکچرر: پٹسبرگ
ASIN: B006ZBAXSW
تاریخ پہلی دستیابی: 4 مئی 2014
اضافی مدد کے لیے، آپ ملاحظہ کر سکتے ہیں۔ Amazon.com پر پروڈکٹ کا صفحہ.