تعارف
This manual provides essential instructions for the safe and effective installation, operation, and maintenance of the Carrier HK61EA005 OEM Replacement Furnace Control Board. Please read this manual thoroughly before proceeding with any installation or service procedures. Retain this manual for future reference.
حفاظتی معلومات
انتباہ: Installation and servicing of heating, ventilation, and air conditioning (HVAC) equipment can be hazardous due to system pressure, electrical components, and equipment location. Only trained and qualified service personnel should install, repair, or service HVAC equipment. Failure to follow these instructions could result in property damage, personal injury, or death.
- کنٹرول بورڈ کو انسٹال کرنے یا سروس کرنے سے پہلے ہمیشہ فرنس سے بجلی منقطع کریں۔
- Verify all wiring connections are secure and correct according to the furnace manufacturer's specifications.
- حفاظتی شیشے اور دستانے سمیت مناسب ذاتی حفاظتی سامان (PPE) پہنیں۔
- Ensure proper grounding of the furnace system.
پروڈکٹ ختمview
The Carrier HK61EA005 is an OEM replacement furnace control board designed to manage the operational sequences of a furnace, including ignition, fan control, and safety monitoring. This board is compatible with various Carrier furnace models.

تصویر 1: Carrier HK61EA005 Furnace Control Board. This image displays the circuit board with various terminals, jumpers, and components. Key features include the "EASY SELECT" jumper settings for system type, ON/OFF DELAY settings, and terminal blocks for wiring connections such as D, R, W, W2, Y, Y2, G, O, and C. A yellow jumper wire is visible connecting two pins on the board.
سیٹ اپ اور انسٹالیشن
- بجلی کا کنکشن: مین سروس پینل پر فرنس کی تمام برقی طاقت بند کر دیں۔ تصدیق کریں کہ والیوم کا استعمال کرتے ہوئے پاور بند ہے۔tagای میٹر
- پرانے بورڈ تک رسائی حاصل کریں: موجودہ کنٹرول بورڈ کو تلاش کرنے کے لیے فرنس ایکسیس پینل کو کھولیں۔
- دستاویز کی وائرنگ: Before disconnecting any wires, take clear photographs or make a detailed diagram of all wiring connections to the old control board. Note the position and color of each wire.
- تاریں منقطع کریں: Carefully disconnect all wires and connectors from the old control board.
- پرانے بورڈ کو ہٹا دیں: فرنس چیسس سے پرانے کنٹرول بورڈ کو ان ماؤنٹ کریں۔ نوٹ کریں کہ اسے کیسے محفوظ کیا گیا تھا (پیچ، کلپس، وغیرہ)۔
- نیا بورڈ انسٹال کریں: Mount the new HK61EA005 control board in the same location and orientation as the old board. Ensure it is securely fastened.
- وائرنگ جوڑیں: Refer to your photographs or diagram and carefully reconnect all wires and connectors to the corresponding terminals on the new control board. Double-check each connection for accuracy and tightness.
- جمپر کی ترتیبات: Configure the "EASY SELECT" jumpers and ON/OFF DELAY jumpers on the new board to match the settings of the original board or the furnace manufacturer's specifications. These settings typically determine the system type (e.g., AC, HP) and fan delay times. Refer to the furnace wiring diagram for specific requirements.
- رسائی پینل بند کریں: تمام کنکشنز کی تصدیق ہونے کے بعد، فرنس رسائی پینل کو بند اور محفوظ کریں۔
- بجلی کی بحالی: مین سروس پینل پر فرنس میں برقی طاقت بحال کریں۔
آپریٹنگ ہدایات
After successful installation and power restoration, the furnace control board will initiate its normal operating sequence. The board manages the following functions:
- اگنیشن تسلسل: Controls the gas valve and igniter for safe furnace startup.
- پنکھے کا کنٹرول: Manages the indoor blower motor operation based on heating or cooling demands and delay settings.
- حفاظتی نگرانی: Continuously monitors various safety sensors (e.g., flame sensor, limit switches) and will shut down the furnace if a fault is detected.
- ترموسٹیٹ انٹرفیس: Communicates with the thermostat to receive heating and cooling calls.
For specific operational details, refer to your furnace's primary instruction manual.
دیکھ بھال
The HK61EA005 control board itself requires no routine maintenance. However, regular maintenance of the overall furnace system is crucial for its longevity and proper function. This includes:
- ایئر فلٹر کی تبدیلی: Replace or clean the furnace air filter regularly (typically every 1-3 months) to ensure proper airflow.
- سالانہ پیشہ ورانہ معائنہ: Have a qualified HVAC technician inspect and service your furnace annually.
- Clean Flame Sensor: A dirty flame sensor can cause intermittent furnace operation. This should be cleaned by a qualified technician.
کوئی بھی دیکھ بھال کرنے سے پہلے ہمیشہ بھٹی سے بجلی منقطع کریں۔
خرابی کا سراغ لگانا
If the furnace is not operating correctly after installing the new control board, consider the following troubleshooting steps:
- کوئی طاقت نہیں:
- Check the circuit breaker for the furnace.
- Ensure the furnace disconnect switch is in the "ON" position.
- Verify all low-voltagای اور ہائی وولtage connections to the control board are secure.
- Furnace Not Igniting:
- Confirm the thermostat is set to "HEAT" and the temperature is above the ambient room temperature.
- Check for error codes on the control board (if applicable, refer to your furnace manual for code interpretations).
- یقینی بنائیں کہ گیس سپلائی والو کھلا ہے۔
- اس بات کی تصدیق کریں کہ شعلہ سینسر صاف اور صحیح جگہ پر ہے۔
- Fan Not Operating Correctly:
- Check the "ON/OFF DELAY" jumper settings on the control board.
- Ensure the thermostat fan setting is correct (AUTO/ON).
- Verify the fan motor connections to the control board.
- ایرر کوڈز: Many control boards have diagnostic LEDs that flash codes to indicate specific faults. Consult your furnace's original manual for a list of error codes and their meanings.
اگر ٹربل شوٹنگ کے اقدامات سے مسئلہ حل نہیں ہوتا ہے، تو مدد کے لیے ایک قابل HVAC ٹیکنیشن سے رابطہ کریں۔
وضاحتیں
| ماڈل نمبر | HK61EA005 |
| Alternate Model Number | CECOMINOD058414 |
| برانڈ | Carrier (OEM Replacement) |
| مصنوعات کے طول و عرض | 6 x 6 x 6 انچ |
| وزن | 0.01 اونس |
| پہلی تاریخ دستیاب ہے۔ | 8 اکتوبر 2013 |
وارنٹی اور سپورٹ
For warranty information regarding this OEM replacement part, please refer to the terms provided by your original point of purchase or the specific warranty documentation included with the product. For technical support, it is recommended to consult a qualified HVAC technician or the original furnace manufacturer's support resources.





