This instruction manual provides essential information for the safe and effective use of the MSA 497334 Polyurethane Sampling Line Probe. This probe is designed to facilitate remote gas sampling for compatible MSA gas detection instruments, including the FiveStar Alarm, Passport Personal Alarm, ProGard, and Gasport Gas Tester/Monitor. Please read this manual thoroughly before setup, operation, or maintenance to ensure proper functionality and user safety.
The MSA 497334 sampling line probe is a critical accessory for extending the reach of your gas detection system, allowing for sampling in confined spaces or hard-to-reach areas without exposing personnel to potential hazards.
پروڈکٹ ختمview

تصویر 1: MSA 497334 Polyurethane Sampling Line Probe. The image displays the clear polyurethane tubing coiled and held together by a black hook-and-loop strap with the MSA logo in green. One end of the tubing features a silver-colored threaded connector, while the other end has a simpler black connector, both designed for attachment to gas detection equipment.
The MSA 497334 Polyurethane Sampling Line Probe consists of a durable, clear polyurethane tube equipped with specific connectors for secure attachment to MSA gas monitors. Its flexible design allows for easy deployment and retrieval in various industrial and safety applications.
حفاظتی معلومات
Always adhere to the safety guidelines provided with your primary MSA gas detection instrument. This sampling line probe is an accessory and does not replace the safety precautions required for the gas monitor itself.
- Ensure all connections are secure before operation to prevent leaks and inaccurate readings.
- ایس کا معائنہ کریں۔ampling line for kinks, damage, or blockages before each use.
- ایس کا استعمال نہ کریں۔ampling line in environments where it may be exposed to extreme temperatures or corrosive chemicals that could degrade the polyurethane material.
- Always follow confined space entry procedures when using this probe for remote sampجنس
سیٹ اپ
- پیک کھولیں اور معائنہ کریں: احتیاط سے ایس کو ہٹا دیں۔ampling line probe from its packaging. Visually inspect the entire length of the polyurethane tubing and both connectors for any signs of damage, kinks, or obstructions. Do not use if damage is observed.
- Connect to Gas Monitor: ایس کی شناخت کریں۔ampling inlet port on your compatible MSA gas monitor (e.g., FiveStar, Passport, ProGard, Gasport). Attach the appropriate connector of the sampling line probe to this port. Ensure the connection is hand-tight and secure to prevent air leaks.
- Connect to Sampling Point (Optional): If using a specific sampling accessory (e.g., a probe tip, filter), attach it to the free end of the sampling line. Ensure this connection is also secure.
- Perform System Check: Before entering a hazardous area, perform a system integrity check as recommended by your gas monitor's manual. This typically involves drawing a known gas sample through the line to verify proper flow and response.
آپریٹنگ ہدایات
The MSA 497334 sampling line probe is designed for remote sampling applications. Follow these steps for operation:
- مانیٹر کی پوزیشن: Place the gas monitor in a safe, accessible location, ensuring it is powered on and functioning correctly.
- Deploy the Sampling Line: Carefully extend the sampling line into the area to be monitored. Avoid sharp bends or kinks that could restrict airflow. Ensure the sampling end is positioned at the desired height or location for accurate gas detection.
- مانیٹر ریڈنگز: Observe the readings on your gas monitor. Allow sufficient time for the sample to travel through the line and for the sensors to stabilize. The response time will be slightly increased due to the length of the sampلنگ لائن.
- Retrieve the Line: ایک بار ایسampling is complete, carefully retract the sampling line, ensuring it does not snag or become damaged.
نوٹ: Always refer to your specific gas monitor's instruction manual for detailed operating procedures, calibration, and alarm settings.
دیکھ بھال
Regular maintenance ensures the longevity and reliability of your sampling line probe.
- صفائی: After each use, especially in dusty or dirty environments, wipe the exterior of the sampling line with a damp cloth. Do not use harsh solvents or abrasive cleaners. Ensure no moisture enters the tubing.
- معائنہ: Periodically inspect the entire length of the tubing for cracks, punctures, or excessive wear. Check connectors for damage or corrosion. Replace the sampling line if any damage is found.
- ذخیرہ: When not in use, coil the sampling line neatly and secure it with the provided strap or a similar method. Store it in a clean, dry environment away from direct sunlight, extreme temperatures, and corrosive substances.
- فلٹر کی تبدیلی (اگر قابل اطلاق ہو): If your setup includes an inline filter, follow the manufacturer's recommendations for inspection and replacement.
خرابی کا سراغ لگانا
| مسئلہ | ممکنہ وجہ | حل |
|---|---|---|
| No or low flow indication on monitor |
|
|
| Inaccurate or slow gas readings |
|
|
If problems persist, contact MSA customer support or a certified service technician.
وضاحتیں
- ماڈل نمبر: 497334
- مواد: Polyurethane
- مطابقت: MSA FiveStar Alarm, Passport Personal Alarm, ProGard, Gasport Gas Tester/Monitor
- Dimensions (Packaged): 7.32 inches (Height) x 2.76 inches (Length) x 0.87 inches (Width)
- وزن (پیکیج): 3.52 اونس
- مینوفیکچرر: ایم ایس اے
- اصل ملک: ریاستہائے متحدہ
وارنٹی اور سپورٹ
For warranty information and technical support regarding the MSA 497334 Polyurethane Sampling Line Probe, please refer to the documentation provided with your primary MSA gas detection instrument or visit the official MSA website. MSA is committed to providing high-quality safety products and customer service.
رابطہ کی معلومات: براہ کرم ملاحظہ کریں۔ ایم ایس اے سیفٹی webسائٹ تازہ ترین رابطے کی تفصیلات اور معاون وسائل کے لیے۔