Lithonia Lighting LE S 2 R

لیتھونیا لائٹنگ LE S 2 R LED ایگزٹ سائن انسٹرکشن دستی

Model: LE S 2 R

تعارف

This manual provides detailed instructions for the installation, operation, and maintenance of the Lithonia Lighting LE S 2 R LED Exit Sign. Please read these instructions carefully before installation and retain them for future reference. This product is designed for commercial and industrial applications, ensuring clear egress path indication.

The Lithonia Lighting LE S 2 R LED Exit Sign features a durable die-cast aluminum construction with a brushed silver finish and red LED letters. It is designed for low energy consumption and offers universal mounting options.

حفاظتی معلومات

  • Installation must be performed by a qualified electrician in accordance with national and local electrical codes.
  • تنصیب یا سروسنگ سے پہلے سرکٹ بریکر پر بجلی منقطع کریں۔
  • فراہمی والیوم کو یقینی بنائیںtage is compatible with the fixture (120/277V AC).
  • گیس یا برقی ہیٹر کے قریب نہ لگائیں۔
  • Mount the fixture securely in locations and at heights where it will not be subjected to tampغیر مجاز اہلکاروں کی طرف سے ering.
  • مینوفیکچرر کی طرف سے تجویز کردہ آلات کا استعمال غیر محفوظ حالت کا سبب بن سکتا ہے۔
  • اس سامان کو اس کے مطلوبہ استعمال کے علاوہ استعمال نہ کریں۔

پیکیج کے مشمولات

تنصیب شروع کرنے سے پہلے تصدیق کریں کہ تمام اجزاء موجود ہیں:

  • LE S 2 R LED Exit Sign unit
  • بڑھتے ہوئے بریکٹ
  • Mounting hardware (screws, nuts, washers)
  • Wiring leads
Components of the Lithonia Lighting LE S 2 R LED Exit Sign

تصویر 1: Included components for the LE S 2 R LED Exit Sign. This image displays the main exit sign unit, a black mounting block, a metal mounting plate, and a bundle of electrical wires, along with various screws and nuts.

سیٹ اپ اور انسٹالیشن

The LE S 2 R LED Exit Sign supports universal mounting (top, end, or back). Follow these steps for proper installation:

مرحلہ 1: تنصیب کے لیے تیاری کریں۔

  1. شروع کرنے سے پہلے سرکٹ بریکر پر بجلی بند کر دیں۔
  2. Determine the desired mounting method (wall, ceiling, or end mount).

Step 2: Mount the Canopy/Bracket

  • For Wall/Ceiling Mount: Secure the mounting bracket to the junction box using appropriate screws. Ensure the bracket is firmly attached.
  • For End Mount: Attach the end-mount canopy to the side of the exit sign housing, then secure the canopy to the wall or ceiling junction box.

مرحلہ 3: بجلی کے کنکشن

This unit is dual-voltage (120/277V AC). Connect the wiring as follows:

  • مربوط کریں۔ سیاہ تار from the exit sign to the 120V AC hot wire from the supply.
  • مربوط کریں۔ سرخ تار from the exit sign to the 277V AC hot wire from the supply.
  • مربوط کریں۔ سفید تار from the exit sign to the غیر جانبدار تار from the supply.
  • مربوط کریں۔ green (ground) wire from the exit sign to the زمینی تار from the supply.
  • Cap off any unused hot wires securely.

WARNING: Incorrect wiring can cause damage to the unit or electrical shock. Consult a qualified electrician if unsure.

Step 4: Attach the Exit Sign Housing

  1. Carefully align the exit sign housing with the mounted bracket.
  2. Secure the housing to the bracket using the provided screws. Ensure there is no exposed hardware after installation.
زاویہ دار view of the installed Lithonia Lighting LE S 2 R LED Exit Sign

تصویر 2: زاویہ دار view of the Lithonia Lighting LE S 2 R LED Exit Sign, showing its brushed silver finish and illuminated red "EXIT" letters. This image represents the sign after successful installation.

سامنے والا view of the installed Lithonia Lighting LE S 2 R LED Exit Sign

تصویر 3: سامنے والا view of the Lithonia Lighting LE S 2 R LED Exit Sign, clearly displaying the red "EXIT" text against the silver background. This view is typical of the sign's appearance when installed.

آپریٹنگ ہدایات

Once properly installed and wired, the Lithonia Lighting LE S 2 R LED Exit Sign operates automatically when power is supplied.

  • عام آپریشن: When AC power is present, the LED "EXIT" letters will illuminate continuously.
  • This model does not include a battery backup feature. It requires continuous AC power to operate.

دیکھ بھال

The Lithonia Lighting LE S 2 R LED Exit Sign requires minimal maintenance due to its LED light source and durable construction.

  • صفائی: Periodically clean the exterior surface with a soft, damp کپڑا کھرچنے والے کلینر یا سالوینٹس کا استعمال نہ کریں۔
  • معائنہ: Regularly inspect the sign for any visible damage or loose connections.
  • ایل ای ڈی لمبی عمر: The integrated LED light source is designed for long-term operation, typically up to 10 years, and does not require bulb replacement.

WARNING: Always disconnect power before performing any maintenance or cleaning.

خرابی کا سراغ لگانا

If the exit sign is not functioning as expected, refer to the following troubleshooting guide:

مسئلہ ممکنہ وجہ حل
Sign does not illuminate. No AC power supply. Check circuit breaker and ensure power is restored. Verify wiring connections.
Sign flickers or dims. Loose wiring connection or incorrect voltage. Disconnect power and check all wiring connections. Ensure correct voltage (120V or 277V) is applied.
Sign is damaged. Physical impact or internal component failure. Contact customer support for replacement or repair options. Do not attempt to repair internal components.

If troubleshooting steps do not resolve the issue, contact Lithonia Lighting customer support.

وضاحتیں

فیچر تفصیل
ماڈل نمبر LE S 2 R
برانڈ لیتھونیا لائٹنگ
طاقت کا منبع AC
والیومtage 120/277 Volts (Dual-voltagای ان پٹ)
واٹtage 2 واٹ
ہلکی قسم ایل ای ڈی
مواد ایلومینیم
ختم کرنا Brushed Silver (with White interior finish)
رنگ Silver (housing), Red (letters)
چڑھنے کی قسم Universal (Wall, Ceiling, End Mount)
مصنوعات کے طول و عرض 9.4 x 12.8 x 1.75 انچ
شے کا وزن 4.24 پاؤنڈ
بیٹریاں Not included, Not required (No battery backup)
تعمیل Meets NFPA life safety regulations

وارنٹی اور سپورٹ

The Lithonia Lighting LE S 2 R LED Exit Sign comes with a 5 سال کی وارنٹی خریداری کی تاریخ سے. یہ وارنٹی عام استعمال کے تحت مواد اور کاریگری میں نقائص کا احاطہ کرتی ہے۔

For warranty claims, technical support, or further assistance, please contact Acuity Brands Lighting Inc. customer service. Refer to the official Lithonia Lighting webتازہ ترین رابطے کی معلومات کے لیے سائٹ۔

مینوفیکچرر: Acuity Brands Lighting Inc.

متعلقہ دستاویزات - LE S 2 R

پریview LXNY New York Approved Steel Exit Sign Installation and Safety Guide | Lithonia Lighting
Detailed installation instructions, safety precautions, and warranty information for the LXNY New York Approved Steel Exit Sign by Lithonia Lighting. Ensure proper setup and operation.
پریview لیتھونیا لائٹنگ LRP/LRP2 LED Edge-Lit ایمرجنسی ایگزٹ سائن انسٹالیشن اور مینٹیننس گائیڈ
لیتھونیا لائٹنگ LRP/LRP2 سیریز 120/277V LED Edge-Lit Emergency Exit Signs کے لیے جامع تنصیب، معائنہ اور دیکھ بھال کی ہدایات، بشمول DC فلیشر اور قابل سماعت الارم کی خصوصیات کے ساتھ اختیارات F، FA، اور FI۔
پریview Lithonia Lighting WLTE Wet Location Exit Sign Installation Instructions
Comprehensive installation guide for Lithonia Lighting WLTE Wet Location Exit Signs, covering safety, wall, ceiling, and end mount installations, operation, maintenance, and troubleshooting.
پریview لیتھونیا لائٹنگ کوانٹم ایل کیو ایم سیریز ایل ای ڈی ایگزٹ سائنز - تکنیکی تفصیلات
Detailed specifications for the Lithonia Lighting Quantum LQM Series LED Exit Signs. This document covers features, electrical and battery specifications, mounting dimensions, ordering information, and compliance standards for these durable, energy-efficient emergency lighting solutions.
پریview لیتھونیا لائٹنگ ای ڈی جی آر ایم سرفیس ماؤنٹ ایل ای ڈی رننگ مین سائن انسٹالیشن ہدایات
This document provides detailed installation instructions for the Lithonia Lighting EDGRM Surface Mount LED Running Man Sign. It includes safety warnings, package contents, and step-by-step guidance for ceiling, wall, surface, and recessed mounting. Ensure proper electrical connections and adherence to all safety regulations.
پریview Lithonia Lighting LED Combo Exit & Emergency Light Installation Instructions
Comprehensive installation, operation, and maintenance guide for Lithonia Lighting's LED Combo Exit & Emergency Light, covering safety, mounting procedures, wiring, and battery backup.