Notifier FMM 1

NOTIFIER FMM-1 Monitor Module Instruction Manual

Model: FMM 1

1. تعارف

This manual provides essential information for the proper installation, operation, and maintenance of the Notifier FMM-1 Monitor Module. The FMM-1 is designed to monitor a circuit of normally open contact devices in a fire alarm system. It is an integral component for ensuring the safety and reliability of your fire detection system.

2. حفاظتی معلومات

Always adhere to local codes, standards, and regulations when installing and maintaining fire alarm equipment. Installation and servicing should only be performed by qualified personnel. Disconnect all power before servicing. Failure to follow these instructions may result in property damage, serious injury, or death.

  • یقینی بنائیں کہ تنصیب یا دیکھ بھال سے پہلے بجلی منقطع ہے۔
  • Follow all wiring diagrams and instructions provided by Notifier.
  • Do not operate the module outside its specified environmental limits.
  • ماڈیول کو صاف اور دھول اور ملبے سے پاک رکھیں۔

3. مصنوعات کی تفصیل اور خصوصیات

The Notifier FMM-1 is a compact monitor module designed for use with Notifier intelligent fire alarm control panels. It provides a single initiating device circuit (IDC) for monitoring normally open contact devices such as manual pull stations, waterflow switches, or supervisory switches. The module communicates with the control panel using the FlashScan protocol, allowing for fast and reliable communication.

Notifier FMM-1 Monitor Module

شکل 3.1: سامنے view of the Notifier FMM-1 Monitor Module, showing its compact design and terminal connections.

Multiple Notifier FMM-1 Monitor Modules in original packaging

Figure 3.2: Multiple Notifier FMM-1 Monitor Modules packaged in a box, indicating new, original packaging.

4. انسٹالیشن اور سیٹ اپ

The FMM-1 module is typically installed in a standard 4-inch square electrical box. It is designed for surface or flush mounting. Refer to the specific wiring diagrams provided with your Notifier fire alarm control panel for detailed connection instructions.

4.1 وائرنگ

Connect the module to the Signaling Line Circuit (SLC) of the fire alarm control panel and to the initiating device circuit (IDC) according to the system's design and Notifier's documentation. Ensure proper polarity and termination for all connections.

4.2 خطاب کرنا

Each FMM-1 module must be assigned a unique address on the SLC loop using the rotary switches on the module. Consult your control panel's manual for valid address ranges and programming procedures.

ویڈیو 4.1: ایک اوورview of the Notifier FMM-1 Monitor Module, showcasing its physical appearance and key features. This video provides a visual guide to the module's design.

5. آپریٹنگ ہدایات

Once properly installed and addressed, the FMM-1 module operates automatically as part of the fire alarm system. It continuously monitors the connected initiating device circuit for changes in state (e.g., a pull station being activated, a waterflow switch closing). Upon detecting an alarm or supervisory condition, the module transmits this information to the fire alarm control panel, which then initiates the appropriate system response.

6 دیکھ بھال

Regular maintenance is crucial for the reliable operation of the FMM-1 module and the overall fire alarm system. Refer to NFPA 72 (National Fire Alarm and Signaling Code) and local authority having jurisdiction (AHJ) requirements for specific testing and maintenance schedules.

  • سالانہ معائنہ: Visually inspect the module and its connections for any signs of damage, corrosion, or loose wiring.
  • فنکشنل ٹیسٹنگ: Periodically test the initiating devices connected to the FMM-1 to ensure they properly trigger an alarm or supervisory signal at the control panel.
  • صفائی: If necessary, gently clean the module's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.

7 خرابیوں کا سراغ لگانا

If the FMM-1 module or its associated circuit is indicating a fault condition on the fire alarm control panel, consider the following:

مسئلہممکنہ وجہحل
Module Fault/TroubleIncorrect wiring, short circuit, open circuit on IDC, incorrect addressing, module failure.Verify wiring connections and polarity. Check for shorts or opens on the IDC. Confirm correct address setting. If issues persist, replace the module.
No Response from DeviceDevice not properly connected, device failure, wiring issue on IDC.Check connections at the initiating device and the FMM-1. Test the initiating device independently. Inspect IDC wiring for breaks or damage.

For complex issues, contact a certified fire alarm technician or Notifier technical support.

8. وضاحتیں

  • برانڈ: مطلع کرنے والا
  • ماڈل: FMM 1
  • حصہ نمبر: FMM-1
  • UPC: 643485653585
  • مینوفیکچرر: نوٹیفائر
  • آئٹم کا وزن: 5.6 اونس
  • پیکیج کے طول و عرض: 6.5 x 5.75 x 1.9 انچ
  • رنگ: Ivery
  • تاریخ پہلی دستیابی: 28 اگست 2015

9. وارنٹی اور سپورٹ

For warranty information and technical support, please refer to the official Notifier website or contact your authorized Notifier distributor. Keep your purchase receipt for warranty claims.

Notifier Official Webسائٹ: www.notifier.com

متعلقہ دستاویزات - FMM 1

پریview NOTIFIER AFP-200 اینالاگ فائر پینل - تکنیکی وضاحتیں اور خصوصیات
تفصیل سے اوپرview NOTIFIER AFP-200 اینالاگ فائر پینل کا، اس کی خصوصیات، سسٹم کی صلاحیت، وضاحتیں، ہم آہنگ آلات، اور پروگرامنگ کے طریقوں کا احاطہ کرتا ہے۔ ایجنسی کی فہرست اور مصنوعات کی معلومات پر مشتمل ہے۔
پریview پروٹیکٹوائر لائنر ہیٹ ڈیٹیکٹر EPR اور EPR-M سیریز: تکنیکی وضاحتیں اور انسٹالیشن گائیڈ
نوٹیفائر کے پروٹیکٹوائر لائنر ہیٹ ڈیٹیکٹر EPR اور EPR-M سیریز کے لیے جامع گائیڈ۔ مصنوعات کی خصوصیات، تکنیکی وضاحتیں، کیمیائی مزاحمت، تنصیب کی ضروریات، اور صنعتی آگ کا پتہ لگانے والے ایپلی کیشنز کے لیے دستیاب لوازمات کا احاطہ کرتا ہے۔
پریview NOTIFIER AFC-600 Intelligent Addressable Fire Panel with FlashScan®
Detailed technical specifications and features of the NOTIFIER AFC-600 Intelligent Addressable Fire Panel, including its FlashScan® protocol, AWACS™™ sensing technology, programming options, system modules, and compatibility with various devices.
پریview Notifier SLC Wiring Manual: Intelligent Control Panel Installation Guide
Comprehensive wiring manual for Notifier Intelligent Control Panel SLC devices. Covers installation, wiring requirements, device specifications, and safety precautions for fire alarm systems, supporting various Notifier FACPs.
پریview نوٹیفائر ESD ڈیجیٹل مارکیٹنگ ہیلپ گائیڈ: انسپائر، سیلف ٹیسٹ، سی ایل ایس ایس
NOTIFIER کے نئے انسپائر فائر سیفٹی سسٹمز، سیلف ٹیسٹ ڈیٹیکٹرز، اور کنیکٹڈ لائف سیفٹی سروسز (CLSS) کو فروغ دینے کے لیے ESD شراکت داروں کے لیے ڈیجیٹل مارکیٹنگ کی حکمت عملیوں، سوشل میڈیا، اور کوآپٹ ایڈورٹائزنگ کے لیے ایک جامع گائیڈ۔
پریview NOTIFIER N16 Fire Alarm Control Panel - Scalable, Connected Life Safety System
Explore the NOTIFIER N16 Fire Alarm Control Panel (FACP) from Honeywell, featuring a 10" touchscreen, scalable capacity for intelligent addressable devices, and integration with Connected Life Safety Services (CLSS). Learn about its features, specifications, and compatible components for advanced fire detection and evacuation.