Cata PCB Switch Unit

Cata PCB Switch Unit for Extractor Hoods - Instruction Manual

Model: PCB Switch Unit (Compatible with various B&Q, Cata, Designair, Cooke & Lewis models)

1. تعارف

This manual provides essential instructions for the installation, operation, and maintenance of your Cata PCB Switch Unit, a genuine replacement part designed for various extractor hood models from B&Q, Cata, Designair, and Cooke & Lewis. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. حفاظتی معلومات

3. پروڈکٹ ختمview

The Cata PCB Switch Unit is a replacement control board for extractor hoods, featuring multiple buttons for various functions such as fan speed control and lighting. It includes a wiring harness for connection to the main power supply and other components of the hood.

Cata PCB Switch Unit with multi-colored wires extending from one end.

تصویر 1: Cata PCB Switch Unit. This image shows the black rectangular control unit with a bundle of multi-colored wires emerging from one end, ready for connection.

اوپر view of the Cata PCB Switch Unit showing five silver control buttons.

تصویر 2: اوپر view of the control unit. This image displays the top surface of the black rectangular unit, featuring five distinct silver-colored push buttons for operational control.

زاویہ دار view of the Cata PCB Switch Unit, highlighting the buttons and wiring.

تصویر 3: زاویہ دار view of the control unit. This image provides an angled perspective of the black unit, clearly showing the five silver control buttons and the attached wiring harness.

4. ہم آہنگ ماڈلز

This PCB Switch Unit is a genuine replacement part compatible with the following extractor hood models from B&Q, Cata, Designair, and Cooke & Lewis:

Always verify the compatibility with your specific appliance model before proceeding with installation.

5. سیٹ اپ اور انسٹالیشن

اہم: Due to the electrical nature of this component, installation should only be performed by a qualified professional or someone with extensive experience in appliance repair and electrical work. Incorrect installation can lead to electrical hazards, damage to the appliance, or void the warranty.

5.1 پری انسٹالیشن کے مراحل

  1. پاور منقطع کریں: Locate the circuit breaker for your kitchen or the specific extractor hood and switch off the power supply completely. Verify that the power is off using a voltagای ٹیسٹر
  2. Access the Existing Unit: Carefully remove any covers, filters, or panels necessary to access the existing PCB switch unit within your extractor hood. Refer to your extractor hood's original manual for specific disassembly instructions.
  3. دستاویز کنکشن: Before disconnecting any wires, take clear photographs or make detailed diagrams of all existing wire connections to the old PCB unit. Note the color and position of each wire.
  4. پرانے یونٹ کو ہٹا دیں: Disconnect all wires from the old PCB unit and carefully remove it from its mounting.

5.2 Installation of New Unit

  1. ماؤنٹ نیو یونٹ: Position the new Cata PCB Switch Unit in the same location as the old unit. Secure it using the original mounting hardware, if applicable.
  2. وائرنگ جوڑیں: Using your documented connections (photos/diagrams), carefully connect each wire from the extractor hood's harness to the corresponding terminal on the new PCB switch unit. Ensure all connections are firm and secure. Double-check all connections before proceeding.
  3. محفوظ تاریں: Ensure that all wires are neatly routed and secured to prevent them from being pinched or damaged during reassembly.
  4. Reassemble Hood: Carefully reassemble any covers, filters, or panels that were removed. Ensure all components are properly seated and secured.

5.3 پوسٹ انسٹالیشن چیک

  1. بجلی کی بحالی: Once installation is complete and all covers are securely in place, restore power to the extractor hood at the circuit breaker.
  2. ٹیسٹ کے افعال: Test all functions of the extractor hood, including fan speeds and lighting, to ensure the new PCB switch unit is operating correctly.

6. آپریٹنگ ہدایات

The operation of the extractor hood is controlled via the buttons on the PCB Switch Unit. While specific functions may vary slightly depending on your extractor hood model, the general operation typically includes:

Refer to your original extractor hood's user manual for detailed instructions on specific button functions and operational modes.

7 دیکھ بھال

The Cata PCB Switch Unit itself requires minimal maintenance. However, proper care of your extractor hood will ensure the longevity of all its components, including the switch unit.

8 خرابیوں کا سراغ لگانا

If you experience issues after installing the new PCB Switch Unit, consider the following troubleshooting steps:

If troubleshooting steps do not resolve the issue, it is recommended to contact a qualified appliance technician or the manufacturer's support for further assistance.

9. وضاحتیں

برانڈکیٹا
پروڈکٹ کی قسمPCB Switch Unit for Extractor Hoods
ہم آہنگ ماڈلزAPOLO 600, APOLO 700, APOLO 900, CH60BK, CH60SS, CH70SS, CH90SS, CHK60BK, CHK60SS, CHK70BK, CHK70SS, CHK90BK, CHK90SS, CHKL60SS
پروڈکٹ کا وزن160 گرام
ASINB019OYMOJW
کارخانہ دارCATA

10. وارنٹی اور سپورٹ

For information regarding warranty coverage, please refer to the original purchase documentation or contact the retailer where the product was acquired. As this is a replacement part, its warranty may be subject to the terms and conditions of the original appliance or the part itself.

For technical support or further inquiries, please contact Cata customer service or your appliance service provider.

آپ ملاحظہ کر سکتے ہیں۔ Cata Store on Amazon for more information on Cata products.

متعلقہ دستاویزات - PCB Switch Unit

پریview CATA GK-4500 Decorative Extractor Hood - User Manual and Installation Guide
Comprehensive user manual and installation guide for the CATA GK-4500 decorative extractor hood. Learn about installation, maintenance, cleaning, and safety instructions.
پریview CATA GC-DUAL Decorative Extractor Hood User Manual
Comprehensive user manual for the CATA GC-DUAL Decorative Extractor Hood, covering installation, safety, operation, maintenance, and legal information. Includes detailed control panel descriptions.
پریview CATA PROFESSIONAL 750 / 750 L Kitchen Extractor Hood: Operating and Installation Manual
Detailed operating and installation instructions for the CATA PROFESSIONAL 750 / 750 L kitchen extractor hood. Includes installation guidelines, electrical connection details, cleaning procedures, and safety information.
پریview Cata Decorative Extractor Hood: Installation, Use, and Maintenance Manual
Comprehensive user manual for Cata decorative extractor hoods, covering installation, operation, safety guidelines, maintenance, and troubleshooting. Learn how to properly install, use, and care for your Cata kitchen hood.
پریview CATA Cooker Hood User Manual: Operation, Settings, and Troubleshooting
Comprehensive user manual for CATA cooker hoods, covering operation, control panel functions, settings for ducted and recirculation modes, lighting, connectivity, fan speed adjustments, timer functions, filter cleaning, and troubleshooting FAQs. Includes instructions in English, Spanish, French, Portuguese, and German.
پریview CATA LENA & WANDA Kitchen Extractor Hood: Installation, Use, and Maintenance Manual
Comprehensive guide for installing, using, and maintaining CATA LENA and WANDA kitchen extractor hoods. Includes safety instructions, troubleshooting, and warranty information.