Notifier LEM-320

نوٹیفائر LEM-320 Loop Expander Module User Manual

Model: LEM-320

1. تعارف

This manual provides essential information for the proper installation, operation, and maintenance of the Notifier LEM-320 Loop Expander Module. The LEM-320 is designed to expand the capacity of compatible fire alarm control panels by providing additional Signaling Line Circuits (SLCs).

2. حفاظتی معلومات

Always observe the following safety precautions during installation, operation, and maintenance of the LEM-320 module:

3. پروڈکٹ ختمview

The Notifier LEM-320 is a Loop Expander Module designed to interface with a compatible Loop Control Module (LCM-320) to extend the system's capacity for addressable devices. It functions as a daughter board, providing additional even-numbered Signaling Line Circuits (SLCs) to the fire alarm control panel.

Notifier LEM-320 Loop Expander Module, top view

تصویر 3.1: اوپر view of the Notifier LEM-320 Loop Expander Module, showing various integrated circuits and components.

Notifier LEM-320 Loop Expander Module, angled view

تصویر 3.2: زاویہ دار view of the Notifier LEM-320 module, highlighting the component layout and connection points.

Notifier LEM-320 Loop Expander Module, bottom view

تصویر 3.3: نیچے view of the Notifier LEM-320 module, showing the circuit board traces and mounting points.

4. تنصیب

The LEM-320 module is designed to be mounted as a daughter board onto a compatible Notifier LCM-320 Loop Control Module. Follow these steps for proper installation:

  1. تیاری: Ensure all power to the fire alarm control panel is disconnected. Refer to the LCM-320 manual for specific power-down procedures.
  2. بڑھتے ہوئے مقام کا پتہ لگائیں: Identify the designated mounting headers on the LCM-320 board for the LEM-320 daughter board.
  3. Align Module: Carefully align the connectors on the LEM-320 with the corresponding headers on the LCM-320. Ensure correct orientation to prevent damage.
  4. محفوظ ماڈیول: Gently press the LEM-320 into place until it is firmly seated. Use any provided standoffs or screws to secure the module to the LCM-320, if applicable.
  5. کنکشنز کی تصدیق کریں: Double-check that all connections are secure and that the module is properly seated.
  6. پاور اپ: Restore power to the fire alarm control panel according to the manufacturer's instructions.
  7. سسٹم کی ترتیب: Configure the fire alarm control panel to recognize the newly installed LEM-320 module and its associated SLCs. Refer to the control panel's programming manual for detailed instructions.

نوٹ: Improper installation can lead to system malfunction or damage. Always consult the specific documentation for the LCM-320 and the main fire alarm control panel.

5. آپریشن

The Notifier LEM-320 Loop Expander Module operates as an integral part of the fire alarm control panel system. Once properly installed and configured with the LCM-320, it extends the system's capacity by providing additional Signaling Line Circuits (SLCs).

No direct user interaction is typically required with the LEM-320 module itself after initial installation and system configuration. Its function is to provide the necessary hardware expansion for the fire alarm system.

6 دیکھ بھال

The Notifier LEM-320 module is designed for reliable, long-term operation with minimal maintenance. However, periodic inspection and adherence to general electronic component care practices are recommended:

احتیاط: Do not attempt to repair the module yourself. Refer all servicing to qualified Notifier service personnel.

7 خرابیوں کا سراغ لگانا

If the fire alarm system experiences issues related to SLC communication or device recognition after the LEM-320 installation, consider the following troubleshooting steps:

If issues persist, contact Notifier technical support or a certified fire alarm technician.

8. وضاحتیں

فیچرتفصیل
ماڈل نمبرLEM-320 (Part Number: NLEM320)
کارخانہ دارنوٹیفائر
فنکشنLoop Expander Module for LCM-320
چڑھناDaughter board to LCM-320
شے کا وزن2 پاؤنڈ
بیٹریاں درکار ہیں۔نہیں
بیٹریاں شامل ہیں۔نہیں
پیکیج کی مقدار1

9. وارنٹی اور سپورٹ

For warranty information regarding the Notifier LEM-320 Loop Expander Module, please refer to the official Notifier warranty statement provided with your product or available on the Notifier webسائٹ وارنٹی کی شرائط عام طور پر عام استعمال کے تحت مواد اور کاریگری میں نقائص کا احاطہ کرتی ہیں۔

For technical support, service, or to report issues, please contact your authorized Notifier distributor or Notifier technical support directly. Ensure you have your product model number (LEM-320) and any relevant system information ready when contacting support.

Notifier Contact Information:
Please visit the official Notifier webحالیہ رابطے کی تفصیلات اور معاون وسائل کے لیے سائٹ۔ www.notifier.com

متعلقہ دستاویزات - LEM-320

پریview نوٹیفائر NFS-320 ذہین ایڈریس ایبل فائر الارم سسٹم ڈیٹا شیٹ
نوٹیفائر NFS-320 انٹیلیجنٹ ایڈریس ایبل فائر الارم سسٹم کے لیے جامع ڈیٹا شیٹ، اس کی خصوصیات، ذہین سینسنگ کی صلاحیتوں، فلیش اسکین پروٹوکول، سسٹم کی وضاحتیں، مطابقت پذیر آلات، اور ایجنسی کی منظوریوں کی تفصیل۔
پریview Notifier CA-2 Audio Chassis Installation Guide
Installation instructions and component details for the Notifier CA-2 Audio Chassis, including preparation, assembly, and field-wiring connection access. Covers mounting of FACP, NCA-2, DVC, microphones, and telephones.
پریview FlashScan® ڈیٹا شیٹ کے ساتھ نوٹیفائر AFC-600 ذہین ایڈریس ایبل فائر الارم کنٹرول پینل
نوٹیفائر AFC-600 انٹیلیجنٹ ایڈریس ایبل فائر الارم کنٹرول پینل کے لیے جامع ڈیٹا شیٹ، جس میں اس کی خصوصیات، تصریحات، سسٹم کی صلاحیت، پروگرامنگ کے اختیارات، ہم آہنگ آلات، اور ایجنسی کی منظوریوں کی تفصیل ہے۔ FlashScan® پروٹوکول اور AWACS™™ سینسنگ ٹیکنالوجی کے بارے میں معلومات پر مشتمل ہے۔
پریview Notifier NRX-M711 Radio System Input/Output Module Installation Instructions
Comprehensive installation guide for the Notifier NRX-M711 radio input-output module, detailing its specifications, parts list, wiring, programming, and commissioning for fire alarm systems.
پریview NOTIFIER NION-16C48M (NION-48M) Instruction Manual
This instruction manual provides detailed information on the installation, configuration, and operation of the NOTIFIER NION-16C48M and NION-48M modules, which are components of the UniNet 2000 fire alarm system.
پریview نوٹیفائر LCD-2X20 سیریز ریموٹ فائر اینونسیٹر انسٹالیشن اور آپریشنز مینوئل
Notifier LCD-2X20 Series Remote Fire Annunciators کے لیے جامع گائیڈ، جس میں فائر الارم سسٹم کے لیے تنصیب، آپریشن، وائرنگ، پروگرامنگ، اور تکنیکی وضاحتیں شامل ہیں۔