Notifier NCM F

Notifier NCM-F Network Control Module (Multi Mode Fiber) User Manual

1. تعارف

The Notifier NCM-F is a Network Control Module specifically designed for multi-mode fiber optic communication within a Notifier fire alarm network system. This module facilitates reliable data exchange between various network nodes, including but not limited to CPU-640/3030, NCA, CPU2-640/3030, NCA-2, and DVC units. For proper network functionality, one NCM-F module is required for each network node that utilizes multi-mode fiber connectivity.

2. سیٹ اپ اور انسٹالیشن

Proper installation of the NCM-F module is crucial for system integrity and performance. Follow these steps carefully.

2.1 حفاظتی احتیاطی تدابیر

  • بجلی کا کنکشن: Always ensure that power to the host fire alarm control panel or network node is completely disconnected before attempting any installation or removal of the NCM-F module.
  • الیکٹروسٹیٹک ڈسچارج (ESD) تحفظ: The NCM-F is a static-sensitive device. Wear an anti-static wrist strap and work on an approved anti-static mat to prevent damage from electrostatic discharge. Avoid touching the circuit board components directly.

2.2 Unpacking the Module

Carefully remove the NCM-F module from its anti-static packaging. Retain the packaging for future storage or transport.

Notifier NCM-F module sealed in anti-static bag, front view

تصویر 1: Notifier NCM-F module sealed in its anti-static bag, showing the front side with a static-sensitive device warning label.

Notifier NCM-F module sealed in anti-static bag, rear view

تصویر 2: Notifier NCM-F module sealed in its anti-static bag, showing the rear side with a static-sensitive device warning label and product identification sticker.

2.3 جسمانی تنصیب

  1. ماڈیول اندراج: Gently align the NCM-F module with the designated slot on the compatible Notifier network node (e.g., CPU-640/3030, NCA). Apply even pressure to firmly seat the module into its connector.
  2. Securing the Module: If applicable, use any provided screws or fasteners to secure the NCM-F module within the host network node chassis.

2.4 Fiber Optic Connection

  1. کیبل کی تیاری: Ensure that the multi-mode fiber optic cables are clean and free of dust or debris. Use appropriate fiber cleaning tools if necessary.
  2. منسلک کیبلز: Connect the multi-mode fiber optic cables to the corresponding transmit (TX) and receive (RX) ports on the NCM-F module. It is critical to ensure correct polarity: the transmit port of one device must connect to the receive port of the other, and vice-versa.

2.5 Power-Up and Verification

After all physical connections are made, restore power to the host network node. Observe the system indicators on the host panel to confirm proper module recognition and network communication status. Refer to the host panel's manual for specific diagnostic procedures.

3. آپریٹنگ ہدایات

The Notifier NCM-F module functions as a dedicated communication interface. Its operation is largely passive, facilitating the network communication for the host panel. User interaction primarily occurs through the host fire alarm control panel or network device.

3.1 نیٹ ورک کمیونیکیشن

Once properly installed and configured within the host network node, the NCM-F transparently manages data transmission and reception over the multi-mode fiber optic link. It converts electrical signals from the host panel into optical signals for transmission and vice-versa for reception.

3.2 حیثیت اشارے

The NCM-F module itself typically does not have user-facing indicators. Network status and module health are usually reported by the host network node. Refer to the host network node's manual for specific LED indicators, display messages, or diagnostic menus related to network communication status. These indicators will confirm the proper operation of the NCM-F and the fiber optic link.

4 دیکھ بھال

Regular maintenance helps ensure the longevity and reliable operation of the NCM-F module and the overall network.

4.1 Cleaning Fiber Optic Connections

Periodically inspect and clean fiber optic connectors using only approved fiber optic cleaning tools and procedures. Dust, dirt, and other contaminants can significantly degrade signal quality and lead to communication errors. Never use abrasive materials or solvents not specifically designed for fiber optic cleaning.

4.2 ماحولیاتی حالات

Ensure that the operating environment for the host network node and the NCM-F module remains within the specified temperature and humidity ranges. Extreme conditions can lead to premature module degradation or malfunction.

4.3 فرم ویئر اپڈیٹس

Any necessary firmware updates for the NCM-F module would typically be performed through the host network node. Always refer to the host panel's documentation for specific firmware update procedures and compatibility information.

5 خرابیوں کا سراغ لگانا

If you experience issues with network communication, follow these troubleshooting steps.

5.1 No Network Communication

  • Module Seating: Verify that the NCM-F module is correctly and firmly seated in its designated slot on the host network node.
  • Fiber Optic Connections: Check all fiber optic cable connections for proper seating and correct polarity (TX to RX, RX to TX).
  • کیبل کی سالمیت: Inspect fiber optic cables for any visible damage such as kinks, sharp bends, or breaks. Damaged cables must be replaced.
  • Host Node Status: Ensure the host network node is powered on and functioning correctly according to its own diagnostic indicators.
  • ماڈیول کی شناخت: Access the diagnostic menus of the host panel to confirm that the NCM-F module is recognized by the system.

5.2 Intermittent Communication

  • کنیکٹر کی صفائی: Clean fiber optic connectors on both the NCM-F and the connected device.
  • ڈھیلے کنکشن: Check for any loose fiber optic cable connections that might be causing intermittent signal loss.
  • Environmental Stability: Verify that environmental conditions (temperature, humidity) are stable and within the module's specified operating range.

5.3 Module Not Recognized

  • پاور سائیکل: Perform a controlled power cycle of the host network node.
  • Re-seat Module: Carefully re-seat the NCM-F module in its slot, ensuring proper alignment and connection.
  • تکنیکی معاونت: If issues persist after performing these steps, contact Notifier technical support or your authorized Notifier distributor for further assistance.

6. وضاحتیں

تفصیلاتتفصیل
ماڈل نمبرNCM F
پارٹ نمبرNNCMF
شے کا وزن2 پاؤنڈ
طاقت کا منبعPowered by host network node
آئٹم پیکیج کی مقدار1
بیٹریاں شامل ہیں۔نہیں
بیٹریاں درکار ہیں۔نہیں
کارخانہ دارنوٹیفائر
یو پی سی636836973869
پہلی دستیاب تاریخ24 مئی 2016

7. وارنٹی اور سپورٹ

7.1 پروڈکٹ وارنٹی

For detailed information regarding the warranty coverage for your Notifier NCM-F Network Control Module, please refer to the official warranty statement provided with your original purchase. You may also contact Notifier directly or consult their official webتازہ ترین وارنٹی شرائط و ضوابط کے لیے سائٹ۔

7.2 تکنیکی معاونت

Should you require technical assistance, installation guidance, or encounter issues that cannot be resolved using the troubleshooting steps provided in this manual, please contact Notifier customer support. You can typically find contact information on the Notifier official website or through your authorized Notifier distributor.

متعلقہ دستاویزات - NCM F

پریview High-Speed Network Communications Modules (HS-NCM) by NOTIFIER by Honeywell - Technical Specification
Detailed technical specifications for NOTIFIER's HS-NCM series of High-Speed Network Communications Modules, covering features, interconnections, common specifications, and agency approvals for fire alarm systems.
پریview HS-NCM Series High-Speed Network Communication Modules Data Sheet
The NOTIFIER HS-NCM Series High-Speed Network Communication Modules enable connection of fire alarm control panels and network control displays to the High-Speed NOTI•FIRE•NET™ (NFN). This document details six available module types (fiber-optic and twisted-pair), their features, specifications, compatibility, and agency approvals.
پریview NOTIFIER INSPIRE Series: Panel Configuration Guide
A comprehensive guide to configuring NOTIFIER INSPIRE Series fire alarm panels, detailing N16E and N16X models, components, backboxes, chassis, networking, and more. Includes technical specifications and cross-references.
پریview نوٹیفائر NCM-W, NCM-F نیٹ ورک کمیونیکیشن ماڈیول انسٹالیشن گائیڈ
NOTIFIER NCM-W (ٹوئسٹڈ پیئر) اور NCM-F (فائبر آپٹک) نیٹ ورک کمیونیکیشن ماڈیولز کے لیے تفصیلی انسٹالیشن گائیڈ۔ پروڈکٹ کا احاطہ کرتا ہے۔viewNOTI•FIRE•NET™ سسٹم کے لیے وائرنگ، تشخیص، اور اضافی دستاویزات۔
پریview نوٹیفائر BMP-1 خالی ماڈیول پلیٹ انسٹالیشن گائیڈ
نوٹیفائر BMP-1 خالی ماڈیول پلیٹ کے لیے انسٹالیشن کی ہدایات، جس میں اعلان کنندہ بیک باکسز اور FACP ڈریس پینلز میں اس کے استعمال کا احاطہ کیا گیا ہے، اور اختیاری ماڈیول کی تنصیب کی تفصیل ہے۔
پریview Notifier CA-2 Audio Chassis Installation Guide
Installation instructions and component details for the Notifier CA-2 Audio Chassis, including preparation, assembly, and field-wiring connection access. Covers mounting of FACP, NCA-2, DVC, microphones, and telephones.