The Bailey Brass Breather Vent (BV-SAE N.8) is designed to regulate airflow and filter contaminants in hydraulic cylinders, tanks, and reservoir systems. It features a 40-micron filter element and an SAE 8 thread port, effectively preventing pressure buildup while blocking dust, debris, and airborne particles. This compact brass fitting ensures clean and consistent performance in low-pressure hydraulic setups, extending component life and maintaining system cleanliness.

Bailey Brass Breather Vent with 40 Micron Filter

تصویر: سامنے view of the Bailey Brass Breather Vent, highlighting the 40-micron filter element.

کلیدی خصوصیات

  • PROTECTS HYDRAULICS: Helps prevent dust, dirt, and airborne debris from entering your hydraulic tank or cylinder—ideal for protecting low-pressure systems and extending equipment life.
  • 40 MICRON FILTERING: Built-in 40-micron filter element allows air to flow freely while capturing fine particles, reducing the risk of internal contamination in hydraulic reservoirs and return lines.
  • SAE 8 THREAD PORT: Fitted with a standard SAE 8 thread port for secure, leak-resistant installation into breather fittings on hydraulic cylinders, tanks, and reservoir systems.
  • DURABLE BRASS: Made from corrosion-resistant brass to withstand tough environments, temperature changes, and fluid exposure—ideal for both indoor and outdoor hydraulic setups.
  • COMPACT DROP-IN DESIGN: This breather vent installs easily into most BV-SAE N.8-compatible systems. Compact form fits tight spots, making it ideal for equipment with limited reservoir space.

انسٹالیشن گائیڈ

Proper installation of the breather vent is crucial for optimal performance and system protection. Follow these steps carefully:

  1. پورٹ تیار کریں: Ensure the hydraulic cylinder, tank, or reservoir port is clean and free of debris. The port should be an SAE 8 thread type.
  2. Inspect the Vent: Before installation, visually inspect the breather vent for any damage or manufacturing defects.
  3. Thread the Vent: Carefully thread the Bailey Brass Breather Vent into the designated SAE 8 port. Ensure it is aligned correctly to prevent cross-threading.
  4. محفوظ طریقے سے سخت کریں: Hand-tighten the vent until snug. For a leak-resistant fit, use an appropriate wrench to gently tighten further, but do not overtighten, as this can damage the threads or the vent itself. Refer to your equipment's manual for specific torque recommendations if available.
  5. تنصیب کی تصدیق کریں: Once installed, confirm the vent is securely in place and that there are no visible gaps or misalignments.
طرف view of Bailey Brass Breather Vent showing SAE 8 threads

تصویر: سائیڈ view of the breather vent, illustrating the SAE 8 thread port for secure installation.

آپریشن

Once installed, the Bailey Brass Breather Vent operates passively to maintain optimal pressure balance within your hydraulic system while preventing contamination. The 40-micron filter element allows air to enter and exit the system as fluid levels change (e.g., during cylinder extension/retraction or temperature fluctuations), preventing vacuum or pressure buildup. Simultaneously, it filters out airborne particles, dust, and debris, protecting sensitive internal components from wear and damage. The vent requires no active user intervention during normal operation.

دیکھ بھال

The Bailey Brass Breather Vent is designed for durability and minimal maintenance. However, periodic inspection is recommended to ensure continued optimal performance:

  • بصری معائنہ: Regularly check the exterior of the vent for any signs of physical damage, corrosion, or blockages.
  • Filter Cleanliness: While the 40-micron filter is robust, in extremely dusty or contaminated environments, it may accumulate excessive dirt. If you notice reduced airflow or signs of system contamination, the filter may need cleaning or replacement.
  • صفائی: For light dust accumulation, the exterior of the vent can be wiped clean with a dry cloth. Do not attempt to disassemble the vent or clean the internal filter element with liquids or compressed air, as this can damage the filter media. If the filter appears heavily clogged, replacement is recommended.
  • متبادل: If the vent becomes damaged, corroded beyond repair, or the filter is permanently clogged, replace it with a new Bailey Brass Breather Vent (Part Number 237257) to ensure continued system protection.

خرابی کا سراغ لگانا

Most issues related to the breather vent are straightforward. Here are common problems and their solutions:

مسئلہممکنہ وجہحل
Reduced airflow / System pressure issuesبھرا ہوا فلٹر عنصرInspect the filter. If heavily clogged, replace the breather vent.
Contaminants entering systemDamaged filter element or improper installationInspect the vent for damage. Ensure it is securely tightened. Replace if damaged.
Vent appears looseInsufficient tightening during installationGently tighten the vent into the port. Do not overtighten.
Corrosion on vent exteriorExposure to harsh chemicals or extreme environmentsWhile brass is corrosion-resistant, extreme conditions can affect it. Clean the exterior. If severe, consider replacement.

تکنیکی وضاحتیں

تفصیلاتقدر
آئٹم ماڈل نمبر237257
Filter Micron Rating40 مائکرون
Thread Port SizeSAE 8
موادپیتل
شے کا وزن1.12 اونس
کارخانہ دارBailey Hydraulics

وارنٹی اور سپورٹ

Bailey International stands behind the quality of its products. For specific warranty information regarding your Bailey Brass Breather Vent (Part Number 237257), please refer to the purchase documentation or contact Bailey International directly.

For technical support, product inquiries, or assistance with troubleshooting, please contact Bailey International customer service. You can find contact information on the official Bailey International webسائٹ یا آپ کے پروڈکٹ سپلائر کے ذریعے۔

Note: Always ensure you are using genuine Bailey International replacement parts for optimal performance and to maintain product integrity.

متعلقہ دستاویزات - 237257

پریview بیلی USB چارجر 10 پورٹس کی تنصیب کا دستی
بیلی USB چارجر 10 پورٹس کے لیے جامع انسٹالیشن مینوئل، تفصیلی تکنیکی وضاحتیں، حفاظتی احتیاطی تدابیر، اور آپریشنل رہنما خطوط فراہم کرتا ہے۔ انگریزی، ڈچ، جرمن، اور فرانسیسی سیکشنز کی معلومات شامل ہیں، جو انگریزی میں ضم ہیں۔
پریview بیلی سولر ایل ای ڈی لائٹ سٹرنگ - یوزر مینوئل اور انسٹالیشن گائیڈ
بیلی سولر ایل ای ڈی لائٹ سٹرنگ (ماڈل 145439) کے لیے جامع گائیڈ، جس میں وضاحتیں، حفاظتی انتباہات، آپریشن، انسٹالیشن، اور چارجنگ کے طریقے شامل ہیں۔ بیرونی استعمال، شام سے صبح تک خودکار آپریشن، اور ایڈجسٹ چمک کی خصوصیات۔
پریview بیلی بیڈ سائیڈ ٹیبل اسمبلی کی ہدایات
Comprehensive assembly instructions for the Bailey Bedside Table (Model 43560400/43566143). This guide provides a detailed hardware list, parts identification, step-by-step assembly procedures, and critical safety warnings for safe construction and use.
پریview بیلی چیسٹ آف دراز اسمبلی ہدایات - ماڈل 43560387/43566105
بیلی چیسٹ آف دراز کے لیے اسمبلی کی جامع ہدایات (ماڈل 43560387/43566105)۔ ہارڈ ویئر کی فہرست، حصوں کی شناخت، مرحلہ وار اسمبلی گائیڈ، اور اہم حفاظتی انتباہات شامل ہیں۔
پریview بیلی ایل ای ڈی فلڈ لائٹ گرے 2.0 انسٹالیشن مینوئل
بیلی ایل ای ڈی فلڈ لائٹ گرے 2.0 (100W-150W) کے لیے انسٹالیشن، ہینڈلنگ اور حفاظتی ہدایات۔ وارنٹی معلومات اور تکنیکی وضاحتیں شامل ہیں۔
پریview بیلی کلپ آن پینڈنٹ شیڈ کی تنصیب اور دیکھ بھال کی ہدایات
بیلی کلپ آن پینڈنٹ شیڈ، آئٹم نمبر 22P077 کے لیے تنصیب اور دیکھ بھال کی ہدایات فراہم کرتا ہے۔ حفاظتی احتیاطی تدابیر، اسمبلی کے اقدامات، اور اندرونی استعمال کے لیے دیکھ بھال کے رہنما خطوط شامل ہیں۔