1. تعارف
The Enttec DIN Pixie 73539 is a compact, DIN-rail mountable DMX to LED pixel protocol converter. It is designed to provide flexible control for architectural, commercial, and entertainment lighting installations by converting DMX512 signals into various LED pixel protocols.
This manual provides essential information for the safe and efficient operation of your DIN Pixie. Please read it thoroughly before installation and use.
2. حفاظتی معلومات
WARNING: This unit is intended for indoor use only. Do not expose to rain or moisture. Doing so will void the warranty.
- Never plug this unit into a dimmer.
- Always be sure to mount this unit in an area that will allow sufficient ventilation.
- Label any RJ45/6 DMX connector and DO NOT connect to non-DMX port (e.g., Ethernet Switch). Connecting unlike systems could result in serious damage to Storm8 and equipment.
- All ports feature ESD surge protection and resettable fuses to block external faults and electrical noise propagation.
3. باکس مشمولات
تصدیق کریں کہ تمام آئٹمز باکس میں موجود ہیں:
- Enttec DIN Pixie unit
- DIN ماؤنٹنگ بریکٹ
- USB Type-A to USB 2.0 Type B Cable
4. جسمانی اوورview اور رابطے

شکل 4.1: سامنے view of the Enttec DIN Pixie controller, showing the status LED and branding.

تصویر 4.2: اوپر view of the Enttec DIN Pixie, highlighting the two DMX input ports (DMX 1 and DMX 2) and the enttec.com URL.

شکل 4.3: نیچے view of the Enttec DIN Pixie, showing the USB 2.0 Type-B input and two 3-pin Phoenix SPI output terminals (labeled 1 and 2) with VCC limit 5-48VDC.
4.1. DMX Input (RJ45)
The DIN Pixie features two RJ45 ports for DMX input. These ports are compliant with ANSI E1.27-2.
| پن | فنکشن |
|---|---|
| پن 1 | ڈیٹا + |
| پن 2 | Data - |
| پن 7/8 | گراؤنڈ |
4.2. SPI Output (3 Pin Phoenix)
The unit provides two 3-pin Phoenix connectors for SPI output. These outputs deliver power and data to your LED pixels. Ensure the VCC limit of 5-48VDC is respected.
- 0 وی: Ground connection for the pixel strip.
- ڈیٹا: Data signal for the pixel strip.
- VCC: والیومtage supply for the pixel strip (5-48VDC).
4.3. USB 2.0 Type-B Input
A robust USB Type-B connector is provided for configuration and firmware updates. It is also backward compatible with the Enttec Pixie Driver API for USB-SPI control.
5. سیٹ اپ اور انسٹالیشن
5.1 چڑھنا
The DIN Pixie is designed for DIN-rail mounting. Use the included DIN Mounting Bracket to secure the unit to a standard DIN rail.

شکل 5.1: نیچے view of the Enttec DIN Pixie showing the attached DIN rail mounting clip.
5.2. یونٹ کو طاقت دینا
The DIN Pixie operates on a wide voltage range of 5-48VDC. It can be powered from the same source as your LED pixels via the VCC and 0V terminals on the SPI output connectors. Alternatively, power can be supplied via the USB connection.
5.3. Connecting LED Pixels
Connect your LED pixel strips or dots to the SPI output terminals. Ensure correct polarity (0V, DATA, VCC) and that the voltage supplied matches the requirements of your pixel strips and is within the 5-48VDC limit of the DIN Pixie.
The DIN Pixie supports RGB and RGBW pixel strips and dots.
5.4. DMX Input Connection
Connect your DMX source to the RJ45 DMX input ports. The unit can receive DMX512-A data.
5.5. ترتیب
The DIN Pixie is configurable and updatable via USB using Enttec's free PRO-MANAGER software. This software allows you to:
- Configure DMX starting address.
- Set pixel grouping functions to optimize channel usage.
- Select between control modes.
- Test output sequences (no external data source required).
- فرم ویئر کو اپ ڈیٹ کریں۔
For the latest version of PRO-MANAGER software and drivers, visit the official Enttec webسائٹ: enttec.com
6۔ آپریٹنگ موڈ
The DIN Pixie supports various operating modes, indicated by the status LED:
- آن: Overheating/Error
- 0.5Hz: بیکار
- 2Hz: Standalone playback
- 8Hz: DMX وصول کرنا
- 25Hz: Receiving from USB
6.1. DMX کنٹرول موڈ
When receiving DMX data, the DIN Pixie converts up to 2 DMX universes (1024 channels) into SPI pixel protocols. The DMX starting address and pixel grouping can be configured via PRO-MANAGER.
The unit can be configured to play a show on DMX loss or blackout output, providing a fail-safe mechanism.
6.2. Standalone Playback Mode
The DIN Pixie has inbuilt flash memory for standalone show playback (4000 frames, approximately 100 seconds). Shows can be recorded and uploaded using PRO-MANAGER. Standalone playback can include sequence advance control options such as play count, loop delay, and play on power up.
6.3. USB Control Mode
The DIN Pixie can be controlled directly via the USB Type-B connector using the Enttec Pixie Driver API. This allows for direct control from a computer or compatible device.
7 دیکھ بھال
The Enttec DIN Pixie is designed for reliable operation and requires minimal maintenance.
- صفائی: یونٹ کے بیرونی حصے کو صاف کرنے کے لیے نرم، خشک کپڑا استعمال کریں۔ مائع کلینر یا سالوینٹس استعمال نہ کریں۔
- فرم ویئر اپ ڈیٹس: Periodically check the Enttec website for firmware updates. Keeping the firmware current ensures optimal performance and access to new features. Firmware updates are performed using the PRO-MANAGER software.
- وینٹیلیشن: Ensure the unit is mounted in an area with adequate ventilation to prevent overheating.
8 خرابیوں کا سراغ لگانا
If you encounter issues with your DIN Pixie, refer to the following common troubleshooting steps:
- No Power/LED Indicators Off:
- Check power connections to the VCC/0V terminals or USB port.
- بجلی کی فراہمی والیوم کو یقینی بنائیںtage is within the 5-48VDC range.
- تصدیق کریں کہ طاقت کا منبع فعال ہے۔
- No Pixel Output:
- Confirm correct wiring of 0V, DATA, and VCC to the pixel strips.
- Check if the DMX source is active and sending data (status LED should be 8Hz).
- Verify pixel protocol and DMX starting address settings in PRO-MANAGER.
- Ensure the pixel strips themselves are functional.
- DMX Input Not Detected (LED 8Hz not flashing):
- Check DMX cable connections.
- Ensure the DMX source is transmitting.
- Confirm the DMX source is using USITT DMX512-A protocol.
- PRO-MANAGER Connection Issues:
- یقینی بنائیں کہ USB کیبل محفوظ طریقے سے منسلک ہے۔
- Install the correct FTDI drivers for your operating system. Refer to the Enttec website for driver information.
- Restart PRO-MANAGER and reconnect the USB cable.
- Overheating/Error (LED ON):
- یونٹ کے ارد گرد مناسب وینٹیلیشن کی جانچ پڑتال کریں.
- Ensure the ambient temperature is within the operating range (0°C to 50°C).
- Reduce the load on the SPI outputs if possible.
For further assistance, please contact Enttec support or visit their website for detailed guides and FAQs.
9. وضاحتیں
| فیچر | تفصیلات |
|---|---|
| کنیکٹرز | 1x USB 2.0 Type-B Input, 2x DMX Input (RJ45), 2x SPI Output (3 Pin Phoenix) |
| ESD تحفظ | Resettable fuse per port |
| آئی پی کی درجہ بندی | آئی پی 20 |
| ایل ای ڈی اشارے | Yes (Power and output status) |
| ان پٹ پروٹوکول | USITT DMX512-A |
| Data Output Type | SPI (Supported protocols listed on Enttec webسائٹ) |
| Maximum Output Channels | 2 Universes (1024ch), duplicated on both ports |
| Max. Output Refresh Rate | 40 ایف پی ایس |
| تاخیر | 5 ملی سیکنڈ |
| ان پٹ جلدtage | 5 - 48V DC (via USB/Ether output port VCC terminal) |
| میکس پاور ڈرا | 1.5W |
| Max. Rated Current per screw terminal (VCC / 0V) | 10A |
| کنفیگریشن سافٹ ویئر | PRO-MANAGER |
| فرم ویئر کی تازہ ترین معلومات | PRO-MANAGER |
| Show Recording/Upload | PRO-MANAGER |
| ماحولیاتی آپریٹنگ درجہ حرارت | 0°C سے 50°C (32°F سے 122°F) |
| ماحولیاتی آپریٹنگ نمی | 5-95% (غیر گاڑھا) |
| جسمانی مواد | ABS پلاسٹک |
| ماؤنٹنگ آپشن | DIN |
| یونٹ کا وزن | 95 گرام / 3.3 اوز |
| طول و عرض (H x W x L) | 1.22 x 3.07 x 3.66 انچ (30.9 x 77.9 x 92.98 ملی میٹر) |
| شپنگ وزن | 0.22 کلوگرام / 0.49 پونڈ |
Note: For the most current and detailed specifications, please refer to the official Enttec datasheet on their webسائٹ
10. وارنٹی اور سپورٹ
10.1. وارنٹی
The Enttec DIN Pixie comes with a 2-year return to base manufacturer warranty, supported by 3rd party software. For detailed warranty terms and conditions, please visit the official Enttec webسائٹ
10.2. تکنیکی معاونت
For technical assistance, troubleshooting, or further information, please visit the Enttec website or contact their support team:
- Webسائٹ: www.enttec.com
- سے رجوع کریں۔ webرابطے کی تفصیلات اور معاون وسائل کے لیے سائٹ۔