Pulsar PGiPAIRB4

Pulsar PGiPAIRB4 Inverter Generator Parallel Kit

ہدایت نامہ

تعارف

This manual provides essential instructions for the safe and efficient use of your Pulsar PGiPAIRB4 Inverter Generator Parallel Kit. This kit allows you to connect two compatible Pulsar inverter generators to double their power output, providing increased electrical capacity for various applications, including RV use.

Compatible Pulsar Generator Models: PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO.

حفاظتی معلومات

Always read and understand all safety warnings and instructions in this manual and the manuals of your connected generators before operation. Failure to follow these instructions can result in serious injury or property damage.

  • Ensure all connections are secure before starting generators.
  • Operate generators in a well-ventilated area to prevent carbon monoxide poisoning.
  • گیلے حالات میں کام نہ کریں۔
  • Keep children and pets away from operating equipment.
  • Always turn off generators and disconnect spark plug wires before performing any maintenance or making connections.

پیکیج کے مشمولات

تصدیق کریں کہ تمام اشیاء آپ کے پیکیج میں موجود ہیں:

  • Pulsar PGiPAIRB4 Parallel Kit Unit
  • Connection Cables (integrated)
  • صارف دستی (یہ دستاویز)
Pulsar PGiPAIRB4 Parallel Kit unit with cables

Image: The Pulsar PGiPAIRB4 Parallel Kit unit, showing the main box with receptacles and circuit breakers, and the integrated connection cables extending from it.

سیٹ اپ اور کنکشن

Follow these steps to connect your parallel kit to two compatible Pulsar inverter generators:

  1. تیاری: Ensure both generators are turned off, cooled down, and disconnected from any loads. Place the generators on a level, stable surface in a well-ventilated area.
  2. Connect Parallel Cables: Locate the parallel connection ports on each generator. These are typically color-coded (red and black) and may have specific shapes.
    Close-up of parallel connection cables

    تصویر: ایک قریبی اپ view of the parallel kit's connection cables, showing the red and black connectors designed to plug into the generators.

    Connect the red cable from the parallel kit to the red parallel port on the first generator. Connect the black cable from the parallel kit to the black parallel port on the first generator. Repeat this process for the second generator.
    Close-up of parallel connection adapters

    Image: Various parallel connection adapters and plugs, illustrating the types of connections used for linking generators.

  3. محفوظ کنکشن: Ensure all connections are firmly seated and secure. Loose connections can cause arcing or power interruptions.
  4. فائنل پلیسمنٹ: Position the parallel kit unit in a safe, accessible location, away from exhaust fumes and moisture.
    Two Pulsar generators connected with the parallel kit

    Image: Two Pulsar inverter generators shown from the rear, with the PGiPAIRB4 Parallel Kit connected to their respective parallel ports, demonstrating a complete setup.

آپریٹنگ ہدایات

Once the parallel kit is securely connected to both generators:

  1. Start Generators: Start both inverter generators according to their individual operating instructions. Allow them to run for a few moments to stabilize.
  2. کنیکٹ لوڈز: Plug your electrical loads into the receptacles on the PGiPAIRB4 Parallel Kit.
    • The L14-50 receptacle provides 120/240V output at 50 amps.
    • The L14-30 receptacle provides 120/240V output at 30 amps.
  3. مانیٹر: Observe the generator and parallel kit for proper operation. The circuit breakers on the parallel kit will trip if an overload occurs.
  4. بند کریں: To shut down, first disconnect all loads from the parallel kit. Then, turn off both generators according to their individual instructions. Finally, disconnect the parallel kit cables.

دیکھ بھال

The Pulsar PGiPAIRB4 Parallel Kit requires minimal maintenance. Follow these guidelines:

  • Keep the unit clean and free of dirt, dust, and moisture.
  • Inspect cables and connectors regularly for any signs of wear, damage, or corrosion. Replace if necessary.
  • Store the kit in a dry, protected area when not in use.

خرابی کا سراغ لگانا

مسئلہممکنہ وجہحل
No power output from parallel kit.
  • Generators not started.
  • ڈھیلے رابطے۔
  • سرکٹ بریکر ٹرپ ہو گیا۔
  • Incompatible generators.
  • Ensure both generators are running.
  • Check all parallel cable connections.
  • Reset the circuit breaker on the parallel kit.
  • Verify generators are listed as compatible models.
سرکٹ بریکر کثرت سے ٹرپ کرتا ہے۔
  • اوور لوڈ کی حالت۔
  • Faulty appliance.
  • Reduce the total electrical load.
  • Test appliances individually to identify faulty ones.

وضاحتیں

  • ماڈل: PGiPAIRB4
  • آؤٹ پٹ والیمtage: 120/240V
  • آؤٹ پٹ فریکوئنسی: 60Hz
  • L14-50 Receptacle: 50 Amps
  • L14-30 Receptacle: 30 Amps
  • ہم آہنگ جنریٹرز: Pulsar PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO
  • مصنوعات کے طول و عرض: 12 x 9 x 4 انچ
  • آئٹم کا وزن: 3 پاؤنڈ
  • مینوفیکچرر: پلسر

وارنٹی کی معلومات

For detailed warranty information regarding your Pulsar PGiPAIRB4 Parallel Kit, please refer to the warranty card included with your purchase or visit the official Pulsar Products webسائٹ وارنٹی کے دعووں کے لیے اپنی خریداری کا ثبوت رکھیں۔

کسٹمر سپورٹ

If you have any questions, require technical assistance, or need to order replacement parts, please contact Pulsar Customer Support:

  • Webسائٹ: www.pulsarproducts.com
  • Refer to your product registration or warranty documentation for specific contact numbers or email addresses.

متعلقہ دستاویزات - PGiPAIRB4

پریview پلسر 9500 واٹ ڈوئل فیول انورٹر جنریٹر آپریٹر کا مینوئل
یہ آپریٹر کا دستور العمل Pulsar PGD95BiSCO 9500 واٹ کے ڈوئل فیول انورٹر جنریٹر کے لیے جامع ہدایات فراہم کرتا ہے، جس میں حفاظتی احتیاطی تدابیر، آپریشن، دیکھ بھال، اور خرابیوں کا سراغ لگانا شامل ہے۔
پریview پلسر PG2200BiS انورٹر پٹرول جنریٹر آپریٹر کا دستی
Pulsar PG2200BiS پورٹیبل انورٹر گیسولین جنریٹر کے لیے آپریٹر کا جامع دستی، قابل اعتماد کارکردگی کو یقینی بنانے کے لیے حفاظت، آپریشن، دیکھ بھال، اور خرابیوں کا سراغ لگانا۔
پریview پلسر PG2000iS/PG2300iS پورٹیبل انورٹر جنریٹر آپریٹر کا دستی
یہ آپریٹر کا دستور العمل Pulsar PG2000iS اور PG2300iS پورٹیبل انورٹر گیسولین جنریٹرز کے محفوظ آپریشن، اسمبلی، دیکھ بھال اور خرابیوں کے حل کے لیے ضروری معلومات فراہم کرتا ہے۔ اپنے جنریٹر کو مؤثر اور محفوظ طریقے سے استعمال کرنے کا طریقہ سیکھیں۔
پریview پلسر 1600 واٹ انورٹر جنریٹر آپریٹر کا دستی PGD16iSCO
پلسر PGD16iSCO 1600 واٹ انورٹر جنریٹر کے لیے آپریٹر کا جامع دستی۔ تفصیلی حفاظتی ہدایات، آپریٹنگ طریقہ کار، دیکھ بھال کے نظام الاوقات، ٹربل شوٹنگ گائیڈز، اور محفوظ اور موثر استعمال کے لیے تکنیکی وضاحتیں شامل ہیں۔
پریview پلسر PG2300iSCO انورٹر پٹرول جنریٹر آپریٹر کا دستی
پلسر PG2300iSCO انورٹر گیسولین جنریٹر کے لیے آپریٹر کا جامع دستی۔ اس گائیڈ میں ضروری معلومات شامل ہیں جن میں حفاظتی اصول، پروڈکٹ کی خصوصیات، اسمبلی کی ہدایات، آپریشن کے تفصیلی طریقہ کار، دیکھ بھال کے نظام الاوقات، ٹربل شوٹنگ ٹپس، اور جنریٹر کے محفوظ اور موثر استعمال کے لیے وائرنگ ڈایاگرام شامل ہیں۔
پریview Pulsar PG4500BiSRCO انورٹر جنریٹر آپریٹر کا دستی
Pulsar PG4500BiSRCO انورٹر جنریٹر کے لیے آپریٹر کا دستی، جس میں پٹرول اور ایل پی جی کے دوہری ایندھن کے استعمال کے لیے حفاظت، خصوصیات، آپریشن، دیکھ بھال، اور ٹربل شوٹنگ کا احاطہ کیا گیا ہے۔