OLMO OS-18SRW-230VI & OS-SR18-230VO

OLMO 18,000 BTU ڈکٹ لیس منی سپلٹ ایئر کنڈیشنر اور ہیٹ پمپ یوزر مینوئل

Model: OS-18SRW-230VI & OS-SR18-230VO

1. تعارف

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your OLMO 18,000 BTU Ductless Mini Split Air Conditioner and Heat Pump. Please read this manual thoroughly before installation and use, and retain it for future reference.

OLMO 18,000 BTU Mini Split system showing indoor unit, outdoor unit, remote control, and smartphone app interface.

Figure 1: OLMO 18,000 BTU Mini Split system with indoor unit, outdoor unit, remote, and app interface.

2. حفاظتی معلومات

Always adhere to basic safety precautions to reduce the risk of fire, electric shock, or injury. This appliance is not intended for use by persons with reduced physical, sensory, or mental capabilities unless supervised or instructed concerning its use by a person responsible for their safety.

2.1 عمومی حفاظت

  • پیشہ ورانہ تنصیب کی ضرورت ہے: This is not a DIY system. Installation must be performed by a qualified HVAC technician in accordance with all local and national electrical and safety codes. Improper installation can result in electric shock, fire, water leakage, or other hazards.
  • برقی حفاظت: Ensure the unit is connected to a properly grounded power supply with the correct voltage (230V). Do not operate with wet hands or in wet conditions.
  • ریفریجینٹ: This unit uses R-32 refrigerant. Only qualified personnel should handle refrigerant.
  • کلیئرنس: Maintain adequate clearance around both indoor and outdoor units for proper airflow and maintenance.
  • صفائی: صفائی یا دیکھ بھال کرنے سے پہلے بجلی منقطع کریں۔

3. مصنوعات کے اجزاء

Your OLMO Mini Split system includes the following main components and installation accessories:

Diagram showing components included in the order: Single-Zone Sierra Series indoor unit with remote, outdoor condenser pre-charged with R32, 16ft pre-flared and insulated copper line set, 4/16 AWG connecting cables, and 16ft drainage extension with small accessories.

Figure 2: Included components for the OLMO Mini Split system.

  • انڈور یونٹ: Single-Zone Sierra Series wall-mount air handler.
  • Outdoor Condenser: Pre-charged with R-32 refrigerant.
  • ریموٹ کنٹرول: آسان آپریشن کے لیے۔
  • 16FT Insulated Copper Line Set: Pre-flared for easier connection.
  • 16FT Communication Cable: For connecting indoor and outdoor units.
  • 16FT Drainage Extension: Designed to prevent kinking.
  • چھوٹے لوازمات: Various parts for a complete installation.
Comparison image showing 'No Kink Drainage Extension' with a rubberized hose (included) versus a standard plastic hose (other brands).

Figure 3: Included rubberized drainage hose designed to prevent kinking.

4. تنصیب کے رہنما خطوط

The OLMO Mini Split system requires professional installation. The outdoor condenser comes pre-charged, and a 16-foot installation kit is included to facilitate the process. Ensure the installation site meets all requirements for proper drainage, electrical connections, and structural support.

4.1 پری انسٹالیشن چیک

  • Verify that the power supply matches the unit's requirements (230V).
  • Ensure sufficient space for both indoor and outdoor units, allowing for proper airflow and maintenance access.
  • Confirm that the wall or mounting surface for the indoor unit can support its weight.

4.2 Key Installation Steps (Overview ٹیکنیشن کے لیے)

  1. انڈور یونٹ کو دیوار پر محفوظ طریقے سے لگائیں۔
  2. Install the outdoor condenser on a stable, level surface, ensuring proper vibration isolation.
  3. Connect the pre-flared copper line set between the indoor and outdoor units.
  4. Connect the communication cable and power wiring according to the wiring diagram.
  5. Install the drainage hose, ensuring a continuous downward slope for proper condensate removal.
  6. Evacuate the system using a vacuum pump to remove air and moisture.
  7. Open the refrigerant valves on the outdoor unit.
  8. Perform a leak check and test run the system.

5. آپریٹنگ ہدایات

Your OLMO Mini Split system offers various modes and features for optimal climate control. The unit can be operated using the included remote control or via the OLMO Remote App on your smartphone.

5.1 ریموٹ کنٹرول آپریشن

The remote control allows you to adjust temperature, change operating modes (Cool, Heat, Fan, Dry, Auto), set fan speed, and activate special features like Sleep Mode or Timer functions. Refer to the remote control's dedicated manual for detailed button functions.

5.2 Smart Control via App

The system includes a Smart Kit, enabling control from anywhere using your smartphone and the OLMO Remote App. Download the app from your device's app store:

Image demonstrating the OLMO Remote App on a smartphone, with QR codes for iOS and Android app downloads.

Figure 4: OLMO Remote App interface and download QR codes.

Follow the in-app instructions to connect your unit and access features such as remote temperature adjustment, mode selection, scheduling, and diagnostics.

Living room setting with the OLMO indoor unit installed, highlighting 'Powerful Solutions' features like Smart Connect, Remote Included, Sleep Mode, Turbo/Eco Modes, Multiple Fan Speeds, Timer, Louver Auto Swing, Self Clean Mode, and LED Display.

Figure 5: OLMO Mini Split features for enhanced comfort and control.

5.3 Key Operating Features

  • All-Season Comfort: Provides efficient heating and cooling across a wide temperature range.
  • خاموش آپریشن: Designed for minimal noise during indoor performance.
  • خاموش موڈ: Reduces fan speed for ultra-quiet operation.
  • متغیر رفتار: Inverter technology adjusts compressor speed for precise temperature control and energy efficiency.
  • نیند موڈ: Adjusts temperature automatically for comfortable sleep and energy savings.
  • ٹائمر: مخصوص اوقات میں یونٹ کو آن یا آف کرنے کے لیے پروگرام کریں۔
  • Louver Auto Swing: Automatically adjusts airflow direction for even distribution.
  • سیلف کلین موڈ: Helps prevent mold and bacteria growth on the indoor coil.
  • ایل ای ڈی ڈسپلے: ترتیبات اور حیثیت کا واضح اشارہ فراہم کرتا ہے۔

6 دیکھ بھال

Regular maintenance ensures optimal performance and longevity of your OLMO Mini Split system. Always disconnect power to the unit before performing any maintenance.

6.1 انڈور یونٹ کی دیکھ بھال

  • ایئر فلٹر کی صفائی: The indoor unit's air filters should be cleaned every 2-4 weeks, or more frequently depending on usage and air quality. Gently remove the filters and wash them with lukewarm water and mild detergent. Allow them to dry completely before reinserting.
  • بیرونی صفائی: انڈور یونٹ کے بیرونی حصے کو نرم سے صاف کریں۔amp کپڑا سخت کیمیکل یا کھرچنے والے کلینر کا استعمال نہ کریں۔

6.2 آؤٹ ڈور یونٹ کی دیکھ بھال

  • کنڈلی کی صفائی: Periodically inspect the outdoor coil for dirt, leaves, and debris. Carefully clean the coil with a soft brush or water hose. Avoid bending the fins.
  • کلیئرنس: Ensure that vegetation, snow, or other obstructions do not block airflow around the outdoor unit.
  • نکاسی آب: رکاوٹوں کے لیے کنڈینسیٹ ڈرین لائن کو چیک کریں۔

7 خرابیوں کا سراغ لگانا

تکنیکی مدد سے رابطہ کرنے سے پہلے، دوبارہview درج ذیل عام مسائل اور حل:

مسئلہممکنہ وجہحل
یونٹ آن نہیں ہوتا ہے۔بجلی نہیں، سرکٹ بریکر ٹرپ، ریموٹ کنٹرول بیٹریاں کم۔بجلی کی فراہمی کو چیک کریں، سرکٹ بریکر کو دوبارہ ترتیب دیں، ریموٹ بیٹریاں تبدیل کریں۔
ناکافی کولنگ/ہیٹنگگندے ایئر فلٹرز، بلاک شدہ آؤٹ ڈور یونٹ، غلط موڈ سیٹنگ، کم ریفریجرینٹ۔Clean air filters, clear obstructions from outdoor unit, verify mode, contact technician for refrigerant check.
غیر معمولی شور۔ڈھیلے حصے، پنکھے کی رکاوٹ، ریفریجرینٹ بہاؤ کا شور (عام)۔Inspect for loose parts or obstructions. If persistent or loud, contact technician.
انڈور یونٹ سے پانی کا رساوBlocked drain line, improper installation.Check and clear drain line. If issue persists, contact technician.

If troubleshooting steps do not resolve the issue, please contact OLMO technical support.

8. وضاحتیں

The following table outlines the key specifications for the OLMO 18,000 BTU Ductless Mini Split Air Conditioner and Heat Pump (Model OS-18SRW-230VI & OS-SR18-230VO).

Detailed specifications table for various OLMO indoor and outdoor models, including power supply, capacity, cooling/heating BTUs, SEER2, HSPF, dimensions, noise levels, refrigerant type, and pipe lengths.

Figure 6: Comprehensive specifications for OLMO Mini Split models.

تفصیلاتقدر
برانڈELM
ماڈل کی معلوماتOS-18SRW-230VI & OS-SR18-230VO
کولنگ پاور18,000 برٹش تھرمل یونٹس (BTU)
کارکردگی (SEER2)21 SEER2
صلاحیت1.5 ٹن
والیومtage230 وولٹ (AC)
ریفریجرینٹR-32
تنصیب کی قسماسپلٹ سسٹم
مصنوعات کے طول و عرض40 x 48 x 40 انچ (مجموعی طور پر)
خصوصی خصوصیاتSilent Mode, Variable Speed
رنگسفید

9. وارنٹی اور سپورٹ

Your OLMO Mini Split system is backed by a limited warranty:

  • کمپریسر: 5 سال محدود وارنٹی
  • حصے: 2 سال محدود وارنٹی
OLMO Mini Split system with certifications (UL Listed, AHRI Certified, Energy Star, Blue Fin Condenser, NEEP) and warranty details (5 years compressor, 2 years parts).

Figure 7: Product certifications and warranty information.

For technical assistance or warranty claims, free US-based technical support is available. Please refer to your purchase documentation for contact details or visit the official OLMO webسائٹ

متعلقہ دستاویزات - OS-18SRW-230VI & OS-SR18-230VO

پریview OLMO ایئر کنڈیشننگ سسٹمز: سیرا سیریز منی اسپلٹس، تھرو دی وال، اور پی ٹی اے سی یونٹس
OLMO کے توانائی سے موثر ایئر کنڈیشننگ حل کی رینج دریافت کریں، بشمول انورٹر ٹیکنالوجی منی اسپلٹ سسٹمز (سیرا سیریز)، تھرو دی وال AC، اور پیکڈ ٹرمینل ایئر کنڈیشنرز (PTAC)۔ تفصیلی وضاحتیں، خصوصیات، اور مصنوعات کی معلومات تلاش کریں۔
پریview اولمو وال ماؤنٹڈ منی سپلٹ ایئر کنڈیشننگ سسٹم کی تنصیب کا دستی
اولمو وال ماونٹڈ منی اسپلٹ ایئر کنڈیشننگ سسٹمز کے لیے انسٹالیشن مینوئل، حفاظتی ہدایات کا احاطہ کرتا ہے، انڈور اور آؤٹ ڈور یونٹس کے لیے سائٹ کا انتخاب، اور ماؤنٹنگ پلیٹس، پائپنگ، اور برقی کنکشن کے لیے تنصیب کے تفصیلی مراحل۔ ماڈل نمبرز OS-09SRW-115VI بذریعہ OS-36SRW-230VO شامل ہیں۔
پریview اولمو سیرا سیریز ریموٹ کنٹرولر ہدایات
Olmo Sierra Series سنگل زون ایئر کنڈیشننگ ریموٹ کنٹرولر کو چلانے کے لیے جامع ہدایات، مختلف طریقوں، فنکشنز اور ٹربل شوٹنگ کا احاطہ کرتی ہیں۔
پریview OLMO وال ماونٹڈ منی سپلٹ ایئر کنڈیشننگ سسٹم: استعمال اور انسٹالیشن مینوئل
OLMO ملٹی سیرا وال ماونٹڈ منی اسپلٹ ایئر کنڈیشننگ سسٹمز کے لیے جامع استعمال اور انسٹالیشن مینوئل، OS-RM09SW-230VI، OS-RM12SW-230VI، OS-RM18SW-230VI، اور OS-RM24SW-230VI کا احاطہ کرنے والے ماڈلز۔ آپریشن اور سیٹ اپ کے لیے ضروری معلومات فراہم کرتا ہے۔
پریview OLMO ملٹی زون ملٹی سیرا سیریز انسٹالیشن مینوئل
یہ انسٹالیشن مینوئل OLMO ملٹی زون ملٹی سیرا سیریز وال ماونٹڈ منی اسپلٹ ایئر کنڈیشننگ سسٹم کے لیے تفصیلی ہدایات فراہم کرتا ہے۔ اس میں OS-RMS18-230VO، OS-RMS27-230VO، OS-RMS36-230VO، اور OS-RMS42-230VO ماڈلز کے لیے حفاظتی احتیاطی تدابیر، تنصیب کے طریقہ کار، پائپنگ کی ضروریات، وائرنگ، اور ٹرائل رن کا احاطہ کیا گیا ہے۔
پریview OLMO Sierra Series Mini Split Air Conditioner Installation Manual
This installation manual provides comprehensive guidance for setting up OLMO Single-Zone Sierra Series Wall Mounted Mini Split Air Conditioning Systems. It covers safety precautions, parts identification, operation, installation steps, testing, maintenance, and troubleshooting.